Synchronous Machines MCQs (Set-4)

Why is a plain synchronous motor not inherently self-starting from standstill on fixed-frequency AC?

A Average starting torque zero
B No stator winding
C No rotor field possible
D Infinite pole count

Damper bars can start a synchronous motor through which action?

A Induction-motor action
B DC commutation
C Transformer tap change
D Capacitive rectification

When is rotor DC excitation commonly applied during damper-assisted starting?

A Before any AC supply always
B Near synchronous speed
C Only after shutdown
D At zero stator voltage

After pulling into step, how does speed change with modest shaft-load changes at fixed frequency?

A It falls with slip
B It doubles
C It stays synchronous
D It becomes zero

As a synchronous motor takes more mechanical load, what mainly increases before pull-out?

A Steady slip
B Torque angle
C Pole count
D Supply frequency

If load torque exceeds the motor’s pull-out capability, what happens?

A Speed remains exact forever
B Field current becomes zero
C Loss of synchronism
D Frequency doubles

Which control can change a synchronous motor’s power factor at fixed mechanical load?

A Field excitation
B Shaft bearing size
C Stator pole count only
D Supply phase order only

An underexcited synchronous motor generally operates at what power factor?

A Leading
B Unity always
C Lagging
D Zero frequency

An overexcited synchronous motor generally operates at what power factor?

A Lagging
B Unity always
C Undefined
D Leading

At a suitable excitation for a given load, synchronous motor power factor can be what?

A Always zero
B Unity
C Always negative
D Only lagging

A V-curve of a synchronous motor plots armature current against what at fixed load?

A Rotor speed
B Pole count
C Shaft diameter
D Field current

An inverted-V curve plots power factor against what?

A Rotor speed
B Armature resistance
C Field current
D Load frequency

An overexcited, lightly loaded synchronous condenser supplies what?

A Reactive power
B Prime-mover torque
C DC output
D Slip power

For a grid-connected synchronous motor, mechanical load mainly sets what input component?

A Reactive power only
B Supply frequency
C Real power
D Pole count

At fixed mechanical load, excitation chiefly changes what input component?

A Rotor speed
B Reactive power
C System frequency
D Shaft torque only

What supplies the main magnetic field on a conventional wound-field synchronous motor rotor?

A DC current
B Stator load resistor
C Slip frequency current
D Cooling fan

What is steady-state slip of a synchronized synchronous motor?

A One
B Zero
C Four percent
D Negative one

A six-pole synchronous motor on 50 Hz runs at what speed?

A 500 rpm
B 1500 rpm
C 3000 rpm
D 1000 rpm

A twelve-pole synchronous motor on 60 Hz runs at what speed?

A 600 rpm
B 300 rpm
C 900 rpm
D 1200 rpm

An overexcited synchronous motor can improve a plant’s lagging power factor by supplying what?

A Extra shaft friction
B Zero-sequence voltage
C DC line current
D Leading VARs

What do damper windings help reduce during synchronous operation?

A Pole count
B Stator frequency
C Hunting oscillations
D Rated voltage

What is hunting in a synchronous machine?

A Rotor-angle oscillation
B Core lamination failure
C Constant zero torque
D Brush wear only

For a given motor shaft load, line current is often minimum near which power-factor condition?

A Strong lagging
B Strong leading
C Zero voltage
D Unity power factor

A synchronous motor’s steady speed is set chiefly by which quantities?

A Field current and load
B Frequency and poles
C Stator resistance only
D Shaft diameter

With an ideal stiff grid at fixed frequency, increasing field current alone does what to steady motor speed?

A Doubles it
B Halves it
C Reverses it
D Leaves it unchanged