Why is a plain synchronous motor not inherently self-starting from standstill on fixed-frequency AC?
A Average starting torque zero
B No stator winding
C No rotor field possible
D Infinite pole count
Answer: A. Average starting torque zero. Rapidly reversing relative torque averages to zero before the rotor reaches near synchronous speed.
Damper bars can start a synchronous motor through which action?
A Induction-motor action
B DC commutation
C Transformer tap change
D Capacitive rectification
Answer: A. Induction-motor action. Shorted damper bars develop induction torque while slip exists.
When is rotor DC excitation commonly applied during damper-assisted starting?
A Before any AC supply always
B Near synchronous speed
C Only after shutdown
D At zero stator voltage
Answer: B. Near synchronous speed. The rotor can pull into step when it is close to field speed.
After pulling into step, how does speed change with modest shaft-load changes at fixed frequency?
A It falls with slip
B It doubles
C It stays synchronous
D It becomes zero
Answer: C. It stays synchronous. Load angle changes while steady rotor speed remains locked to stator field.
As a synchronous motor takes more mechanical load, what mainly increases before pull-out?
A Steady slip
B Torque angle
C Pole count
D Supply frequency
Answer: B. Torque angle. The rotor lags the rotating field by a larger load angle.
If load torque exceeds the motor’s pull-out capability, what happens?
A Speed remains exact forever
B Field current becomes zero
C Loss of synchronism
D Frequency doubles
Answer: C. Loss of synchronism. The rotor can no longer stay locked to the stator field.
Which control can change a synchronous motor’s power factor at fixed mechanical load?
A Field excitation
B Shaft bearing size
C Stator pole count only
D Supply phase order only
Answer: A. Field excitation. Adjusting field current changes reactive current and power factor.
An underexcited synchronous motor generally operates at what power factor?
A Leading
B Unity always
C Lagging
D Zero frequency
Answer: C. Lagging. It draws magnetizing reactive power from the supply.
An overexcited synchronous motor generally operates at what power factor?
A Lagging
B Unity always
C Undefined
D Leading
Answer: D. Leading. Extra field excitation makes it supply reactive power to the system.
At a suitable excitation for a given load, synchronous motor power factor can be what?
A Always zero
B Unity
C Always negative
D Only lagging
Answer: B. Unity. Field adjustment can bring line current nearly in phase with voltage.
A V-curve of a synchronous motor plots armature current against what at fixed load?
A Rotor speed
B Pole count
C Shaft diameter
D Field current
Answer: D. Field current. The current first falls and then rises as excitation crosses the unity-power-factor region.
An inverted-V curve plots power factor against what?
A Rotor speed
B Armature resistance
C Field current
D Load frequency
Answer: C. Field current. Power factor peaks near normal excitation and falls on either side.
An overexcited, lightly loaded synchronous condenser supplies what?
A Reactive power
B Prime-mover torque
C DC output
D Slip power
Answer: A. Reactive power. It acts as a controllable source of leading VARs.
For a grid-connected synchronous motor, mechanical load mainly sets what input component?
A Reactive power only
B Supply frequency
C Real power
D Pole count
Answer: C. Real power. More shaft work requires greater real electrical power.
At fixed mechanical load, excitation chiefly changes what input component?
A Rotor speed
B Reactive power
C System frequency
D Shaft torque only
Answer: B. Reactive power. Field current changes VAR demand and power factor.
What supplies the main magnetic field on a conventional wound-field synchronous motor rotor?
A DC current
B Stator load resistor
C Slip frequency current
D Cooling fan
Answer: A. DC current. A DC-excited rotor establishes fixed magnetic poles in rotor coordinates.
What is steady-state slip of a synchronized synchronous motor?
A One
B Zero
C Four percent
D Negative one
Answer: B. Zero. Rotor and rotating field have the same steady speed.
A six-pole synchronous motor on 50 Hz runs at what speed?
A 500 rpm
B 1500 rpm
C 3000 rpm
D 1000 rpm
Answer: D. 1000 rpm. Ns=120×50/6=1000 rpm.
A twelve-pole synchronous motor on 60 Hz runs at what speed?
A 600 rpm
B 300 rpm
C 900 rpm
D 1200 rpm
Answer: A. 600 rpm. Ns=120×60/12=600 rpm.
An overexcited synchronous motor can improve a plant’s lagging power factor by supplying what?
A Extra shaft friction
B Zero-sequence voltage
C DC line current
D Leading VARs
Answer: D. Leading VARs. Its leading reactive output offsets inductive load VAR demand.
What do damper windings help reduce during synchronous operation?
A Pole count
B Stator frequency
C Hunting oscillations
D Rated voltage
Answer: C. Hunting oscillations. Currents induced by rotor oscillations provide damping torque.
What is hunting in a synchronous machine?
A Rotor-angle oscillation
B Core lamination failure
C Constant zero torque
D Brush wear only
Answer: A. Rotor-angle oscillation. The rotor swings about its steady power-angle position after disturbances.
For a given motor shaft load, line current is often minimum near which power-factor condition?
A Strong lagging
B Strong leading
C Zero voltage
D Unity power factor
Answer: D. Unity power factor. At fixed real power and voltage, current magnitude is minimized near unity power factor.
A synchronous motor’s steady speed is set chiefly by which quantities?
A Field current and load
B Frequency and poles
C Stator resistance only
D Shaft diameter
Answer: B. Frequency and poles. Its locked speed is Ns=120f/P.
With an ideal stiff grid at fixed frequency, increasing field current alone does what to steady motor speed?
A Doubles it
B Halves it
C Reverses it
D Leaves it unchanged
Answer: D. Leaves it unchanged. Excitation changes power factor and internal EMF, while synchronous speed remains fixed.