Electricity generation mainly converts what into electrical energy?
A Only existing electricity
B Only reactive power
C Primary energy
D Only line voltage
Answer: C. Primary energy. Mechanical, thermal, chemical or radiant sources are converted into electrical output.
A rotating alternator converts which input into AC electrical power?
A Only DC current
B Mechanical shaft power
C Stored charge only
D Transformer flux only
Answer: B. Mechanical shaft power. A prime mover spins its rotor to induce AC in the stator.
What is the role of a prime mover in a conventional generating unit?
A Drive generator shaft
B Step up voltage
C Measure power factor
D Insulate the bus
Answer: A. Drive generator shaft. A turbine or engine supplies mechanical rotation to the generator.
Generator frequency depends directly on rotor speed and what else?
A Fuel price
B Cooling-water flow
C Number of poles
D Transformer ratio
Answer: C. Number of poles. For a synchronous generator, f=PN/120.
Why is voltage commonly stepped up before long-distance transmission?
A Increase line resistance
B Reduce line current
C Change frequency
D Eliminate all losses
Answer: B. Reduce line current. At the same power, higher voltage means lower current and lower I²R loss.
A kilowatt-hour is a unit of what?
A Power
B Frequency
C Voltage
D Energy
Answer: D. Energy. Energy equals power integrated over time.
A 1 MW unit runs at constant output for 2 hours. How much energy is generated?
A 0.5 MWh
B 1 MW
C 2 MWh
D 2 MW
Answer: C. 2 MWh. 1 MW×2 h=2 MWh.
What does a generating unit’s nameplate capacity state?
A Rated power output
B Daily energy only
C Fuel inventory
D Annual emissions
Answer: A. Rated power output. Capacity is the rated output under specified conditions.
Capacity factor compares actual energy with what benchmark?
A Peak demand only
B Fuel heat content only
C Reactive power
D Rated output over period
Answer: D. Rated output over period. It is actual generation divided by capacity times elapsed time.
A 100 MW unit runs at 50% capacity factor for 24 h. What energy does it produce?
A 50 MWh
B 2400 MWh
C 100 MWh
D 1200 MWh
Answer: D. 1200 MWh. 100×0.5×24=1200 MWh.
A daily load curve plots electrical demand against what?
A Generator speed
B Time
C Pole count
D Impedance
Answer: B. Time. It shows how demand varies throughout the day.
What is base load in a demand profile?
A Persistent minimum demand
B Highest instant demand
C Only reactive demand
D Total yearly energy
Answer: A. Persistent minimum demand. Base load is the relatively continuous portion of demand.
Peak load denotes which demand level?
A Maximum demand
B Minimum demand
C Average voltage
D Rated generator speed
Answer: A. Maximum demand. It is the greatest demand in the specified period.
Load factor equals average demand divided by what?
A Energy tariff
B Installed capacity only
C Peak demand
D Reactive power
Answer: C. Peak demand. It describes how uniformly a system uses its peak capacity.
Average demand is 50 MW and peak is 100 MW. What is load factor?
A 2
B 0.5
C 50
D 100
Answer: B. 0.5. 50/100=0.5, or 50%.
Diversity factor compares sum of individual maximum demands with what?
A Average frequency
B Generator rating only
C Coincident system maximum
D Daily energy
Answer: C. Coincident system maximum. The maxima often occur at different times, so their sum can exceed system peak.
Reserve margin commonly compares available capacity above peak demand with what denominator?
A Peak demand
B Annual energy
C Rated voltage
D Fuel cost
Answer: A. Peak demand. A common definition is (capacity−peak demand)/peak demand.
What is spinning reserve?
A Fuel stored on site
B Disconnected spare cable
C Online unused capacity
D Offline construction capacity
Answer: C. Online unused capacity. Synchronized units can rapidly increase output from unused headroom.
A persistent generation shortfall relative to load tends to make grid frequency do what?
A Fall
B Rise without limit
C Stay fixed automatically
D Reverse phase order
Answer: A. Fall. Insufficient real power causes connected synchronous machines to slow.
Reactive-power support in a power system chiefly helps control what?
A Voltage
B Fuel inventory
C Pole count
D Daily energy
Answer: A. Voltage. VAR supply and absorption influence bus voltage.
Why are large AC generators synchronized before connecting to a live grid?
A Raise fuel heat value
B Reduce pole count
C Eliminate excitation
D Match phase conditions
Answer: D. Match phase conditions. Voltage, frequency, phase order and angle must be compatible.
Dispatch decisions choose what for available generating units?
A Only paint colors
B Only transformer oil
C Rotor pole counts
D Power outputs
Answer: D. Power outputs. System operators schedule and adjust unit outputs to meet demand.
Thermal efficiency of a power station compares electrical output energy with what?
A Reactive output
B Nameplate voltage
C Generator mass
D Fuel heat input
Answer: D. Fuel heat input. It is useful electric energy divided by thermal energy supplied.
Heat rate expresses required fuel heat input per unit of what?
A Peak current
B Electrical energy generated
C Reactive power
D Rotor speed
Answer: B. Electrical energy generated. A lower heat rate means less thermal input per electrical kWh.
If a plant produces 1 MWh from 2 MWh thermal input, what is efficiency?
A 25%
B 50%
C 100%
D 200%
Answer: B. 50%. Electric output divided by thermal input is 1/2=50%.