Difficulty: Hard
Five failures occur over 10,000 operating hours. What is MTBF?
A 1,000 h
B 2,000 h
C 5,000 h
D 10,000 h
Answer: B. 2,000 h. MTBF is operating time divided by failures: 10,000/5 = 2,000 hours.
With constant failure rate and MTBF=1,000 h, what is reliability at 200 h?
A 0.67
B 0.90
C 0.98
D 0.82
Answer: D. 0.82. For an exponential model, R=e^(βt/MTBF)=e^(β0.2)β0.82.
MTBF is 900 h and MTTR is 10 h. What is steady-state availability?
A 98.9%
B 90.0%
C 95.0%
D 99.9%
Answer: A. 98.9%. Availability is MTBF/(MTBF+MTTR)=900/910β98.9%.
An item has MTBF of 2,500 h. What constant failure rate is estimated?
A 0.0002/h
B 0.0020/h
C 0.0004/h
D 0.0040/h
Answer: C. 0.0004/h. For a constant-rate model, failure rate Ξ»β1/MTBF=1/2,500=0.0004 per hour.
An FMEA uses severity 8, occurrence 3, detection 2. What is RPN?
A 24
B 32
C 64
D 48
Answer: D. 48. Risk priority number is the product of severity, occurrence, and detection ratings: 8Γ3Γ2=48.
Two independent series components have reliabilities 0.98 and 0.99. What is system reliability?
A 0.950
B 0.970
C 0.985
D 0.999
Answer: B. 0.970. Series reliability is the product: 0.98Γ0.99=0.9702, approximately 0.970.
Parallel redundant units have reliabilities 0.90 and 0.80. What is combined reliability?
A 0.72
B 0.90
C 0.98
D 0.96
Answer: C. 0.98. Parallel reliability is 1β(0.10Γ0.20)=0.98, assuming independent failures.
A 100 NΒ·m target uses a 0.4 m wrench and 0.1 m inline extension. What wrench setting is needed?
A 80 NΒ·m
B 64 NΒ·m
C 100 NΒ·m
D 125 NΒ·m
Answer: A. 80 NΒ·m. For an inline extension, setting is targetΓwrench length/(wrench length+extension): 100Γ0.4/0.5=80 NΒ·m.
An extension is placed at 90Β° to a torque wrench. What happens to effective length?
A It doubles
B It halves
C It becomes zero
D It is unchanged
Answer: D. It is unchanged. A perpendicular extension does not add to the wrench’s effective length.
A part has a 3,000-cycle life limit and has used 2,740 cycles. How many remain?
A 160
B 260
C 240
D 360
Answer: B. 260. Remaining life is 3,000β2,740=260 cycles.
Independent fault events have probabilities 0.10 and 0.20. What is AND-gate probability?
A 0.02
B 0.10
C 0.28
D 0.30
Answer: A. 0.02. For independent events, an AND gate probability is the product: 0.10Γ0.20=0.02.
The same events feed an OR gate. What is OR probability?
A 0.02
B 0.20
C 0.28
D 0.30
Answer: C. 0.28. P(A or B)=0.10+0.20β0.10Γ0.20=0.28 for independent events.
A monitored component shows a steady vibration rise but remains below limit. What is the sound next step?
A Ignore until failure
B Remove all sensors
C Reset the limit
D Trend and investigate
Answer: D. Trend and investigate. A worsening trend should be investigated under the approved maintenance program before limits are exceeded.
A component is nearing its approved life limit. What is the correct planning action?
A Extend life informally
B Schedule timely replacement
C Erase cycle records
D Wait for a defect
Answer: B. Schedule timely replacement. Life-limited parts must be planned for replacement by their approved time or cycle limit.
Severe corrosion is found in a concealed area. What guides treatment?
A Approved corrosion data
B General cleaning only
C Unverified shop practice
D Paint color chart
Answer: A. Approved corrosion data. Corrosion removal and protection should follow approved data and applicable manufacturer instructions.
After corrosion removal, what should be restored?
A Bare metal surface
B Unsealed lap joint
C Approved protective finish
D Damaged primer
Answer: C. Approved protective finish. Protective coatings should be restored to limit renewed corrosion.
A flight-control linkage is opened during maintenance. What may be required before release?
A Paint thickness check
B Fuel sample
C Cabin pressure test
D Independent inspection
Answer: D. Independent inspection. Flight-control work may require an independent inspection under the applicable maintenance program.
A torque wrench is dropped or overloaded. What action protects measurement integrity?
A Keep using it
B Recalibrate or inspect
C Increase torque setting
D Remove serial number
Answer: B. Recalibrate or inspect. Impact or overload can affect accuracy, so the tool should be checked per calibration procedures.
A repeated defect appears after each flight. Which data should be analyzed first?
A Discrepancy and repair history
B Passenger manifest
C Paint batch only
D Route map
Answer: A. Discrepancy and repair history. Repeated discrepancies and repair actions help reveal whether the same underlying cause remains.
A maintenance task is interrupted mid-step. What reduces restart error?
A Rely on memory
B Remove the task card
C Mark status and next step
D Close the work order
Answer: C. Mark status and next step. Recording the exact status and next required action supports a safe handover and restart.
An NDI indication is near an acceptance threshold. Who should evaluate it?
A Any available technician
B Parts vendor only
C Aircraft owner alone
D Qualified personnel using criteria
Answer: D. Qualified personnel using criteria. Inspection indications must be evaluated by qualified personnel against approved acceptance criteria.
A functional test passes but the original defect remains intermittent. What should follow?
A Close the discrepancy
B Continue fault isolation
C Erase fault history
D Replace unrelated parts
Answer: B. Continue fault isolation. An intermittent defect requires further isolation and evidence that the original cause was corrected.
Why should maintenance findings be fed into reliability analysis?
A Identify recurring patterns
B Reduce documentation
C Remove scheduled tasks
D Change aircraft identity
Answer: A. Identify recurring patterns. Fleet findings and repeat defects can reveal systemic issues and support maintenance-program improvement.
An aircraft receives a new maintenance instruction. What should technicians use?
A Old printed copy
B Uncontrolled summary
C Current approved revision
D Memory alone
Answer: C. Current approved revision. Using current approved technical data prevents work to superseded procedures or limits.
A task is signed off without required inspection evidence. What is missing?
A Aircraft configuration
B Fuel quantity
C Tool storage
D Documented verification
Answer: D. Documented verification. Required inspections and results must be documented to support maintenance approval and traceability.