Why is an ordinary single-phase induction motor not self-starting?
A No stator flux
B Infinite rotor resistance
C Zero net starting torque
D No iron core
Answer: C. Zero net starting torque. At standstill, equal forward and backward field components produce opposing torques.
The double-revolving-field model resolves a single-phase pulsating field into what?
A Three DC fields
B Two opposite rotating fields
C One stationary magnet
D Four equal phases
Answer: B. Two opposite rotating fields. Two equal counter-rotating fields explain zero starting torque.
What does an auxiliary starting winding create with the main winding?
A Phase-displaced field
B DC supply only
C Zero rotor current
D Mechanical clutch
Answer: A. Phase-displaced field. A phase difference between winding currents creates starting torque.
Which single-phase motor type commonly gives high starting torque with a start capacitor?
A Capacitor-start motor
B Shaded-pole motor
C Permanent-split capacitor only
D Synchronous reluctance motor
Answer: A. Capacitor-start motor. A start capacitor increases phase displacement and starting torque.
A shaded-pole motor is commonly used for which kind of load?
A Large traction drive
B Heavy crane hoist
C High-power compressor
D Small fan
Answer: D. Small fan. Its simple construction and low starting torque suit small fans.
A split-phase motor may disconnect its auxiliary start winding with what?
A Commutator
B Transformer tap
C Slip ring
D Centrifugal switch
Answer: D. Centrifugal switch. A speed-operated switch opens the start winding after acceleration.
In a capacitor-run motor, the run capacitor normally remains connected when?
A Only at standstill
B During operation
C Only during faults
D Never
Answer: B. During operation. The capacitor continues to produce a phase shift in the auxiliary winding.
A permanent-split-capacitor motor typically does not need what?
A Stator winding
B Rotor bars
C AC supply
D Centrifugal start switch
Answer: D. Centrifugal start switch. Its auxiliary winding and run capacitor stay connected continuously.
If one supply phase is lost while a three-phase motor is running, what hazard increases?
A Guaranteed speed increase
B Zero current everywhere
C Overheating
D Reverse rotation
Answer: C. Overheating. Single phasing produces severe current imbalance and overheating.
A three-phase induction motor that has stopped under single-phasing will usually do what?
A Fail to start normally
B Start at rated torque
C Run synchronously
D Generate DC
Answer: A. Fail to start normally. A missing phase cannot produce the normal balanced rotating starting field.
A small supply-voltage unbalance can produce what in motor line currents?
A Perfectly equal currents
B Larger current unbalance
C Zero slip
D Higher frequency
Answer: B. Larger current unbalance. Negative-sequence effects can amplify current imbalance and heating.
Worn bearings can increase which motor loss?
A Rotor copper efficiency
B Pole count
C Supply frequency
D Friction loss
Answer: D. Friction loss. Extra mechanical friction raises heat and reduces shaft efficiency.
For a centrifugal fan under similarity conditions, power demand varies approximately with speed to what power?
A Third power
B First power
C Second power
D Zero power
Answer: A. Third power. Fan affinity laws give approximately P∝n³ for similar operating conditions.
What is synchronous speed for four poles on 60 Hz?
A 1800 rpm
B 900 rpm
C 1200 rpm
D 3600 rpm
Answer: A. 1800 rpm. Ns=120×60/4=1800 rpm.
A four-pole 60 Hz motor runs at 1746 rpm. What is slip?
A 1%
B 6%
C 3%
D 10%
Answer: C. 3%. (1800−1746)/1800=0.03.
What is synchronous speed of a two-pole motor on 50 Hz?
A 1500 rpm
B 750 rpm
C 6000 rpm
D 3000 rpm
Answer: D. 3000 rpm. Ns=120×50/2=3000 rpm.
What is synchronous speed of an eight-pole motor on 50 Hz?
A 500 rpm
B 1000 rpm
C 750 rpm
D 1500 rpm
Answer: C. 750 rpm. Ns=120×50/8=750 rpm.
At 60 Hz and 3% slip, what is rotor current frequency?
A 3 Hz
B 1.8 Hz
C 18 Hz
D 60 Hz
Answer: B. 1.8 Hz. fr=sf=0.03×60=1.8 Hz.
If air-gap power is 15 kW at 4% slip, what is rotor copper loss?
A 0.6 kW
B 4 kW
C 14.4 kW
D 15.6 kW
Answer: A. 0.6 kW. sPag=0.04×15=0.6 kW.
At 15 kW air-gap power and 4% slip, what developed mechanical power?
A 0.6 kW
B 14.4 kW
C 15.6 kW
D 4 kW
Answer: B. 14.4 kW. (1−s)Pag=0.96×15=14.4 kW.
A shaft delivers 9 kW from 10 kW electrical input. What is overall efficiency?
A 10%
B 90%
C 111%
D 99%
Answer: B. 90%. η=9/10×100=90%.
A motor develops 14.4 kW mechanical power at 150 rad/s. What torque is developed?
A 9.6 N·m
B 150 N·m
C 2160 N·m
D 96 N·m
Answer: D. 96 N·m. T=P/ω=14400/150=96 N·m.
Near no load, rotor current is comparatively small because what is small?
A Stator voltage
B Pole count
C Slip
D Magnetizing flux
Answer: C. Slip. Small slip induces a low rotor EMF and hence a relatively small rotor current.
What does a motor nameplate rated speed usually lie relative to synchronous speed?
A Slightly below
B Exactly equal
C Well above
D Always zero
Answer: A. Slightly below. An induction motor needs positive slip to produce rated motoring torque.
For a normal three-phase cage motor, rotor current flows in what path?
A External slip rings
B Separate DC exciter
C Shorted bars and rings
D Commutator brushes
Answer: C. Shorted bars and rings. Induced current circulates through cage bars and end rings.