Electrical Measurements MCQs (Set-4)

At balance, why does a DC potentiometer avoid loading the cell being tested?

A It shorts the cell
B It draws no test current
C It adds a shunt
D It measures resistance

Two unknown EMFs balance at lengths 30 cm and 60 cm on the same uniform wire. What is their ratio?

A 2:1
B 1:2
C 1:4
D 4:1

Which bridge is commonly used to measure inductance with a standard capacitor?

A Maxwell bridge
B Wheatstone bridge
C Schering bridge
D Kelvin bridge

Which AC bridge measures capacitance and dielectric loss?

A Maxwell bridge
B Kelvin bridge
C Schering bridge
D Wheatstone bridge

Which bridge is suited to a high-Q inductor?

A Wien bridge
B Kelvin bridge
C Hay bridge
D Schering bridge

Which bridge can determine frequency using a resistor-capacitor network?

A Kelvin bridge
B Maxwell bridge
C Schering bridge
D Wien bridge

A bonded strain gauge senses mechanical strain through which electrical change?

A Resistance change
B Frequency doubling
C Open-circuit voltage
D Inductance cancellation

Gauge factor equals fractional resistance change divided by what?

A Applied voltage
B Supply frequency
C Load current
D Mechanical strain

What electrical property changes in a typical resistance temperature detector?

A Resistance
B Inductance only
C Capacitance only
D Frequency only

A thermocouple develops voltage through which effect?

A Hall effect
B Skin effect
C Photoelectric effect
D Seebeck effect

An LVDT primarily measures which quantity?

A Light intensity
B Insulation resistance
C Angular frequency
D Linear displacement

A piezoelectric sensor is especially suitable for which measurement?

A Dynamic vibration
B Steady DC resistance
C Static temperature
D Long-term DC force

A Hall-effect sensor responds directly to which field?

A Gravitational field
B Magnetic field
C Acoustic field
D Thermal field

Which device converts incident light into an electrical signal?

A Shunt resistor
B Moving-iron meter
C Photodiode
D Current transformer

How many distinct digital codes can an ideal 8-bit ADC produce?

A 256
B 8
C 128
D 1024

For a 0–10 V ideal 10-bit ADC, approximately how wide is one quantization step?

A 0.977 mV
B 97.7 mV
C 1 V
D 9.77 mV

Averaging many readings mainly reduces which type of measurement error?

A Fixed calibration offset
B Zero-mean random noise
C Wrong scale factor
D Broken sensor

Why must a measuring system have adequate bandwidth?

A To increase resistance
B To remove grounding
C To follow signal changes
D To double resolution

An unwanted current flows through multiple instrument grounds. What can this cause?

A Perfect isolation
B Ground-loop interference
C Zero offset always
D Higher quantization bits

In a four-wire resistance measurement, what do the separate sense leads carry ideally?

A Negligible current
B Full load current
C Half source current
D AC only

What is the main purpose of guarding in high-resistance measurements?

A Increase meter burden
B Short the sample
C Change AC frequency
D Reduce leakage error

Which source is usually applied by an insulation-resistance tester?

A High DC voltage
B Low AC current
C Radio-frequency pulses
D Three-phase power

What is compared in a null measurement?

A Peak against RMS
B Current against frequency
C Balance against reference
D Power against energy

A 10× probe is connected, but the oscilloscope channel is set to 1×. How is displayed voltage affected?

A Ten times too high
B Unaffected
C Ten times too low
D Zero always

In a digital meter, what does resolution describe?

A Maximum safe voltage
B Smallest indicated increment
C Calibration date
D Battery lifetime