A shunt resistor for an ammeter is connected how relative to the meter movement?
A In parallel
B In series
C Across the voltage source
D In the ground only
Answer: A. In parallel. The shunt diverts most current around the sensitive movement.
A high-resistance multiplier turns a galvanometer into which instrument?
A Ammeter
B Energy meter
C Voltmeter
D Frequency meter
Answer: C. Voltmeter. A series multiplier limits current while measuring higher voltage.
What is typical of an ordinary moving-iron instrument scale near zero?
A It is exactly linear
B It is reversed
C It is crowded
D It has no marks
Answer: C. It is crowded. Deflecting torque varies roughly with current squared, crowding low readings.
For a well-designed PMMC instrument, scale spacing is generally what?
A Crowded near zero
B Uniform
C Logarithmic
D Random
Answer: B. Uniform. Deflecting torque is proportional to DC coil current, giving a linear scale.
Approximately how does moving-iron deflecting torque vary with current?
A As 1/I
B As V only
C As frequency only
D As I²
Answer: D. As I². Magnetic energy change makes the deflecting torque proportional to current squared in the idealized case.
What factor makes an electrodynamic wattmeter respond to AC active power?
A sinφ only
B Frequency alone
C cosφ
D Coil resistance only
Answer: C. cosφ. Its average torque is proportional to VI cosφ.
At 230 V and 2 A with unity power factor, a wattmeter reads what?
A 460 W
B 115 W
C 232 W
D 920 W
Answer: A. 460 W. Real power is VI cosφ=230×2×1=460 W.
A 2 kW heater runs for 3 hours. What energy does a meter register?
A 0.67 kWh
B 2 kWh
C 9 kWh
D 6 kWh
Answer: D. 6 kWh. Energy is power times time: 2×3=6 kWh.
A digital meter marked 1000 impulses/kWh registers how many impulses for 1 kWh?
A 100
B 500
C 1000
D 2000
Answer: C. 1000. The meter constant directly states impulses per kilowatt-hour.
What is the nominal current ratio of a 100/5 A current transformer?
A 5:1
B 100:1
C 20:1
D 500:1
Answer: C. 20:1. Primary-to-secondary rated currents are 100/5=20.
A 11 kV/110 V potential transformer has what nominal voltage ratio?
A 10:1
B 100:1
C 50:1
D 1000:1
Answer: B. 100:1. 11000/110=100 for primary-to-secondary voltage.
A 100/5 A CT carries 5 A in its secondary. Nominal primary current is what?
A 5 A
B 20 A
C 100 A
D 500 A
Answer: C. 100 A. The rated current ratio maps 5 A secondary to 100 A primary.
When the expected value is uncertain, which multimeter range is a sensible starting point?
A Highest suitable range
B Lowest range
C Continuity mode always
D No range
Answer: A. Highest suitable range. Beginning high reduces the chance of overloading a manual-range meter.
For measuring voltage with little circuit loading, a digital voltmeter should have what input resistance?
A High
B Low
C Zero
D Negative
Answer: A. High. High input resistance draws little current from the circuit.
Before using an ordinary ohmmeter, what should be done to the circuit?
A Apply rated voltage
B Short the meter leads externally
C Raise frequency
D De-energize it
Answer: D. De-energize it. The ohmmeter supplies its own test current and is intended for an unpowered circuit.
At Wheatstone-bridge balance, what current passes through the null detector?
A Zero
B Supply current
C Maximum current
D Load current
Answer: A. Zero. Equal midpoint potentials produce no detector current.
A bridge has arm ratios 2:4 and 3:6. What is its state?
A Open-circuited
B Resonant
C Overloaded
D Balanced
Answer: D. Balanced. Both ratios equal one-half, so the detector sees zero potential difference.
A four-wire resistance measurement reduces error mainly from what?
A Supply frequency
B Test-lead resistance
C Ambient light
D Magnetic polarity
Answer: B. Test-lead resistance. Separate current and voltage leads remove most lead-drop contribution.
Which bridge is especially suited to accurate low-resistance measurement?
A Maxwell bridge
B Schering bridge
C Wien bridge
D Kelvin double bridge
Answer: D. Kelvin double bridge. The Kelvin double bridge compensates for lead and contact resistances.
Which instrument is commonly used for insulation resistance in megohms?
A Ammeter
B Megohmmeter
C Wattmeter
D Energy meter
Answer: B. Megohmmeter. A megohmmeter applies a suitable test voltage to measure high insulation resistance.
On an oscilloscope, the vertical axis usually represents what?
A Time
B Voltage
C Frequency only
D Resistance
Answer: B. Voltage. The vertical deflection shows instantaneous signal amplitude.
What does a standard oscilloscope time base control along the horizontal axis?
A Time
B Voltage
C Current
D Power factor
Answer: A. Time. The horizontal sweep is calibrated in seconds per division.
A waveform spans four horizontal divisions at 1 ms/div. Its period is what?
A 0.25 ms
B 4 ms
C 1 ms
D 400 ms
Answer: B. 4 ms. Period = four divisions × 1 millisecond per division.
A sampled instrument operates at 1 ksample/s. What is its Nyquist frequency?
A 500 Hz
B 250 Hz
C 1000 Hz
D 2000 Hz
Answer: A. 500 Hz. The Nyquist frequency is half the sampling rate.
For a sinusoidal voltage, how does RMS value relate to its peak magnitude?
A Peak times √2
B Peak divided by 2
C Equal to peak
D Peak divided by √2
Answer: D. Peak divided by √2. The RMS value of a pure sine wave is Vpeak/√2.