What energy conversion occurs in a DC motor?
A Electrical to mechanical
B Mechanical to electrical
C Heat to light
D AC to DC only
Answer: A. Electrical to mechanical. A motor converts electrical input into shaft mechanical output.
In a running DC motor, induced back EMF has which polarity relative to supply?
A It aids supply
B It opposes supply
C It is always zero
D It is alternating externally
Answer: B. It opposes supply. Lenz’s law makes the rotational EMF oppose the applied armature voltage.
Ignoring brush drop, which equation is correct for a DC motor?
A Eb=V−IaRa
B Eb=V+IaRa
C Eb=IaRa−V
D Eb=V/Ia
Answer: A. Eb=V−IaRa. Supply voltage is shared between back EMF and armature resistance drop.
Why is starting armature current high if full voltage is applied directly?
A Field flux is infinite
B Armature resistance is infinite
C Shaft torque is zero
D Back EMF is zero
Answer: D. Back EMF is zero. At standstill, back EMF is zero and the small armature resistance limits current.
What is the chief purpose of a DC motor starter?
A Limit starting current
B Increase line frequency
C Eliminate field flux
D Reverse commutator
Answer: A. Limit starting current. Starting resistance controls armature current until back EMF develops.
A no-voltage release in a starter protects against what?
A High brush friction
B Core eddy currents
C Unexpected restart
D Excessive line frequency
Answer: C. Unexpected restart. It releases the handle after supply failure so the motor does not restart unattended.
Electromagnetic torque of a DC motor is proportional to what?
A Flux divided by speed
B Voltage times resistance
C Speed squared only
D Flux times armature current
Answer: D. Flux times armature current. The torque equation is T=kΦIa.
At constant flux, what happens to developed torque if armature current doubles?
A It halves
B It doubles
C It quadruples
D It stays zero
Answer: B. It doubles. Torque is directly proportional to armature current when flux is unchanged.
Which product represents developed electromagnetic power in a DC motor?
A VIaRa
B Ia²/Ra
C Φ/Ra
D EbIa
Answer: D. EbIa. The converted mechanical power before rotational losses is back EMF times armature current.
Approximately, motor speed is proportional to which ratio?
A Flux to current
B Torque to resistance
C Back EMF to flux
D Current to voltage
Answer: C. Back EMF to flux. From Eb=kΦω, speed is proportional to Eb/Φ.
Where is a DC shunt motor field winding connected?
A In series with armature
B Across each commutator bar
C In the shaft
D Across the supply
Answer: D. Across the supply. A shunt field is connected in parallel with the armature supply.
Which speed behaviour is typical of a DC shunt motor over moderate load changes?
A Unlimited speed change
B Zero speed at light load
C Exact synchronous speed
D Nearly constant speed
Answer: D. Nearly constant speed. Its approximately steady field flux yields relatively good speed regulation.
How is the field winding of a DC series motor connected?
A In series with armature
B Across the supply
C Across interpoles only
D Open at startup
Answer: A. In series with armature. The same load current passes through its series field and armature.
Which motor type typically gives very high starting torque?
A DC shunt motor
B Induction generator
C DC series motor
D Synchronous condenser
Answer: C. DC series motor. High starting current strengthens the series field and produces large torque.
Why must a DC series motor not be operated without a mechanical load?
A It has no armature current
B Its voltage becomes AC
C It may overspeed
D Its poles disappear
Answer: C. It may overspeed. At low current, weak field flux can cause dangerously high speed.
In a cumulative compound motor, how do shunt and series field fluxes combine?
A They cancel exactly
B They are perpendicular
C They aid each other
D They alternate each cycle
Answer: C. They aid each other. The series-field flux assists the shunt-field flux.
In a differential compound motor, the series field does what?
A Aids shunt field
B Opposes shunt field
C Replaces the armature
D Eliminates back EMF
Answer: B. Opposes shunt field. The series-field magnetization subtracts from the shunt field.
To reverse a DC motor’s direction, which connection change works?
A Reverse both armature and field
B Increase both currents
C Reverse armature leads only
D Reduce supply frequency
Answer: C. Reverse armature leads only. Reversing either armature current or field flux reverses torque direction.
If both armature and field polarities are reversed, how does motor direction change?
A It always reverses
B It remains the same
C It becomes random
D It stops permanently
Answer: B. It remains the same. Torque depends on the product ΦIa; reversing both keeps its sign.
At roughly fixed armature voltage, weakening the shunt field tends to do what to speed?
A Increase speed
B Decrease speed
C Make speed zero
D Reverse direction
Answer: A. Increase speed. Since speed is approximately Eb/Φ, lower flux raises speed if conditions permit.
Reducing armature voltage with unchanged field generally provides speed control where?
A Only above base speed
B Below base speed
C At infinite speed
D At fixed synchronous speed
Answer: B. Below base speed. Lower armature voltage reduces back EMF and speed at a given flux.
A motor has V=220 V, Ia=10 A and Ra=1 Ω. What is back EMF, ignoring brush drop?
A 210 V
B 220 V
C 230 V
D 22 V
Answer: A. 210 V. Eb=V−IaRa=220−10=210 V.
If flux is halved at fixed armature current, what happens to developed torque ideally?
A It halves
B It doubles
C It quadruples
D It stays unchanged
Answer: A. It halves. T=kΦIa, so halving Φ halves torque at fixed Ia.
When a shunt motor load increases, its speed usually does what?
A Doubles exactly
B Drops slightly
C Rises without limit
D Becomes synchronous
Answer: B. Drops slightly. Extra armature current increases voltage drop, slightly reducing back EMF and speed.
What produces the field in a permanent-magnet DC motor?
A Shunt field current
B Series field current
C Commutator current only
D Permanent magnets
Answer: D. Permanent magnets. Permanent magnets establish the principal air-gap flux without a field winding.