Two matched 12 V, 60 Ah batteries are connected in parallel. What is nominal capacity?
A 60 Ah at 24 V
B 120 Ah at 12 V
C 120 Ah at 24 V
D 30 Ah at 12 V
Answer: B. 120 Ah at 12 V. Parallel connection keeps voltage the same while adding the capacities of matched batteries.
A 12 V, 60 Ah battery stores how much nominal energy?
A 720 Wh
B 72 Wh
C 5,000 Wh
D 60 W
Answer: A. 720 Wh. Nominal energy is voltage × ampere-hours: 12 × 60 = 720 Wh.
An 80 A alternator supplies 55 A of vehicle loads. What current remains for charging?
A 55 A
B 25 A
C 80 A
D 135 A
Answer: B. 25 A. The difference between alternator output and loads is 80 − 55 = 25 A for battery charging.
Alternator output is 1.4 kW from 1.75 kW mechanical input. Efficiency is what?
A 60%
B 70%
C 80%
D 90%
Answer: C. 80%. Efficiency is output divided by input: 1.4/1.75 = 0.80, or 80%.
A 0.01 Ω cable joint carries 150 A. What voltage drop occurs?
A 0.15 V
B 15 V
C 150 V
D 1.5 V
Answer: D. 1.5 V. Voltage drop is current × resistance: 150 × 0.01 = 1.5 V.
That same 0.01 Ω joint carries 150 A. How much heat is generated?
A 22.5 W
B 225 W
C 1.5 W
D 2,250 W
Answer: B. 225 W. Resistive heating is I²R: 150² × 0.01 = 225 W.
A battery has 12.6 V emf and 0.015 Ω internal resistance. At 200 A, terminal voltage is what?
A 9.6 V
B 12.3 V
C 15.6 V
D 6.0 V
Answer: A. 9.6 V. Internal voltage drop is 200 × 0.015 = 3 V, leaving 12.6 − 3 = 9.6 V.
A parked vehicle draws 40 mA for 30 days. Charge drawn is about what?
A 28.8 Ah
B 2.88 Ah
C 12 Ah
D 40 Ah
Answer: A. 28.8 Ah. 0.04 A × 24 hours/day × 30 days = 28.8 Ah.
The battery disconnects while the alternator is generating. What transient can stress electronics?
A Wheel hop
B Brake fade
C Load dump
D Fuel surge
Answer: C. Load dump. Removing the battery under alternator load can create a high-energy voltage transient known as load dump.
How many main diodes are used in a conventional three-phase full-wave alternator bridge?
A Three
B Six
C Four
D Twelve
Answer: B. Six. A conventional three-phase full-wave bridge uses six main diodes to rectify all phase half-waves.
One alternator rectifier diode fails. Which symptom may appear?
A Higher battery capacity
B More starter torque
C Excessive AC ripple
D Lower lamp resistance
Answer: C. Excessive AC ripple. A failed diode can increase ripple and reduce the alternator’s effective DC output.
Why can a DC starter draw very high current at standstill?
A Back electromotive force is low
B Battery resistance is zero
C Field current is absent
D Starter voltage is infinite
Answer: A. Back electromotive force is low. At zero speed, the motor has little back EMF opposing supply voltage, so armature current is high.
A starter cable becomes hot during cranking. Which check is useful?
A Open-circuit resistance only
B Tire-pressure test
C Alternator belt timing
D Loaded voltage-drop test
Answer: D. Loaded voltage-drop test. Measuring voltage drop while current flows reveals resistance in the high-current starter path.
A starter draws 180 A at 12 V. What electrical input power is approximate?
A 216 W
B 1.5 kW
C 21.6 kW
D 2.16 kW
Answer: D. 2.16 kW. Electrical input power is 12 × 180 = 2,160 W, or 2.16 kW.
A rested, charged 12 V lead-acid battery remains near 10.5 V. Which fault is plausible?
A All cells overcharged
B Loose headlamp bulb
C Open starter relay
D One shorted cell
Answer: D. One shorted cell. A shorted cell removes roughly one cell’s voltage from the six-cell battery total.
An ignition coil has 3 mH inductance and 6 A primary current. Stored energy is what?
A 0.009 J
B 0.108 J
C 0.054 J
D 0.54 J
Answer: C. 0.054 J. Magnetic energy is ½LI² = 0.5 × 0.003 × 6² = 0.054 J.
A load dump clamp protects vehicle electronics by doing what?
A Limiting transient voltage
B Increasing starter current
C Opening every ground
D Raising battery capacity
Answer: A. Limiting transient voltage. Clamping circuitry limits the peak transient voltage seen by vehicle electrical subsystems.
What is the main risk of using an oversized fuse?
A Battery voltage falls
B Alternator stops rotating
C Wiring may overheat
D Relay coil opens
Answer: C. Wiring may overheat. A fuse rated too high may allow damaging current before the conductor is protected.
A short circuit creates a very low-resistance path. What is likely?
A Zero current
B Higher battery capacity
C Lower conductor heating
D Large fault current
Answer: D. Large fault current. With voltage applied across low resistance, current can become excessive and overheat conductors.
Why does alternator output fall if field excitation is reduced?
A Stator wire gets shorter
B Battery gains cells
C Rotor magnetic field weakens
D Rectifier changes frequency
Answer: C. Rotor magnetic field weakens. Lower rotor field flux reduces the voltage induced in the alternator stator.
A high-resistance ground strap can cause what during cranking?
A Higher spark energy
B More wheel torque
C Faster starter speed
D Ground-side voltage loss
Answer: D. Ground-side voltage loss. Resistance in the return path causes a voltage drop that reduces voltage available to the starter.
Why can a battery buffer alternator ripple?
A It stores charge in parallel
B It blocks all DC
C It raises AC frequency
D It opens the field circuit
Answer: A. It stores charge in parallel. The battery’s large electrochemical capacity helps smooth the rectified alternator output.
What does an alternator’s B+ terminal normally carry?
A Charging output to battery
B Starter solenoid ground
C Ignition-coil trigger only
D Lamp-switch return
Answer: A. Charging output to battery. B+ is the alternator’s main positive output connection to the battery and vehicle bus.
Why can a shorted cell reduce a battery’s open-circuit voltage?
A All cells gain resistance
B One cell stops contributing
C Alternator adds voltage
D Starter bypasses the battery
Answer: B. One cell stops contributing. A shorted cell no longer contributes its normal voltage to the series cell stack.
Which practice helps prevent reverse-polarity damage during service?
A Connect cables at random
B Verify polarity before connection
C Remove all fuses first
D Ground both terminals
Answer: B. Verify polarity before connection. Checking positive and negative polarity before connecting prevents damaging reverse-current paths.