A town of 10,000 people uses 135 L/person/day. Demand is what?
A 0.135 MLD
B 13.5 MLD
C 135 MLD
D 1.35 MLD
Answer: D. 1.35 MLD. Demand = 10,000 times 135 L/day = 1,350,000 L/day, or 1.35 MLD.
A 2 MLD supply delivered evenly over 24 hours averages what flow?
A 24 m3/hour
B 48 m3/hour
C 200 m3/hour
D 83.3 m3/hour
Answer: D. 83.3 m3/hour. 2,000 m3/day divided by 24 hours is about 83.3 m3/hour.
Wastewater flow is 500 m3/day at BOD 200 mg/L. BOD load is what?
A 10 kg/day
B 50 kg/day
C 100 kg/day
D 200 kg/day
Answer: C. 100 kg/day. 500,000 L/day times 200 mg/L equals 100,000,000 mg/day, or 100 kg/day.
BOD falls from 80 to 20 mg/L. Removal efficiency is what?
A 75 percent
B 25 percent
C 60 percent
D 80 percent
Answer: A. 75 percent. Removal = (80 – 20)/80 times 100 = 75 percent.
Chlorine dose is 3 mg/L and residual is 0.8 mg/L. Approximate demand is what?
A 0.8 mg/L
B 2.2 mg/L
C 3.0 mg/L
D 3.8 mg/L
Answer: B. 2.2 mg/L. Demand is dose minus residual: 3.0 – 0.8 = 2.2 mg/L.
A 2 MLD demand requires how much storage for four hours of uniform demand?
A 83 m3
B 500 m3
C 333 m3
D 2000 m3
Answer: C. 333 m3. 2,000 m3/day times 4/24 day is about 333 m3.
A clarifier treats 10,000 m3/day over 500 m2. Overflow rate is what?
A 20 m/day
B 5 m/day
C 10 m/day
D 50 m/day
Answer: A. 20 m/day. Surface overflow rate = 10,000/500 = 20 metres per day.
A 500 m3 tank treats 1000 m3/day. Detention time is what?
A 6 hours
B 24 hours
C 48 hours
D 12 hours
Answer: D. 12 hours. HRT = 500/1000 day = 0.5 day, or 12 hours.
Flow is 0.03 m3/s through area 0.015 m2. Velocity is what?
A 0.5 m/s
B 1 m/s
C 4 m/s
D 2 m/s
Answer: D. 2 m/s. Velocity = flow/area = 0.03/0.015 = 2 m/s.
A 2 MLD flow equals about how many cubic metres per second?
A 0.0023 m3/s
B 0.23 m3/s
C 0.023 m3/s
D 2.0 m3/s
Answer: C. 0.023 m3/s. 2,000 m3/day divided by 86,400 seconds/day is about 0.0231 m3/s.
A population of 5000 uses 100 L/person/day. Daily demand is what?
A 0.05 MLD
B 5 MLD
C 50 MLD
D 0.5 MLD
Answer: D. 0.5 MLD. 5000 times 100 L/day equals 500,000 L/day, or 0.5 MLD.
Influent TSS is 200 mg/L and removal is 80 percent. Effluent TSS is what?
A 20 mg/L
B 80 mg/L
C 160 mg/L
D 40 mg/L
Answer: D. 40 mg/L. Remaining concentration = 200 times (1 – 0.80) = 40 mg/L.
A filter treats 6000 m3/day at 5 m/hour. Required area is what?
A 25 m2
B 60 m2
C 50 m2
D 120 m2
Answer: C. 50 m2. 5 m/hour equals 120 m/day; area = 6000/120 = 50 m2.
A contact tank must provide 30 minutes at 1000 m3/hour. Volume is what?
A 500 m3
B 250 m3
C 1000 m3
D 2000 m3
Answer: A. 500 m3. Thirty minutes is 0.5 hour, so volume = 1000 times 0.5 = 500 m3.
A full pipe has diameter 0.5 m and length 100 m. Water volume is about what?
A 7.9 m3
B 19.6 m3
C 39.3 m3
D 78.5 m3
Answer: B. 19.6 m3. Volume = pi times 0.25 squared times 100 = about 19.6 cubic metres.
A plant flow is 4 MLD and 25 percent is lost. Delivered flow is what?
A 1 MLD
B 2 MLD
C 3 MLD
D 4 MLD
Answer: C. 3 MLD. Loss is 1 MLD, leaving 3 MLD delivered.
A 1500 m3/day flow is split equally among three filters. Each receives what?
A 250 m3/day
B 500 m3/day
C 750 m3/day
D 1500 m3/day
Answer: B. 500 m3/day. Equal division gives 1500/3 = 500 m3/day per filter.
Influent BOD is 250 mg/L; effluent is 50 mg/L. Removal is what?
A 20 percent
B 50 percent
C 80 percent
D 200 percent
Answer: C. 80 percent. Removal = (250 – 50)/250 times 100 = 80 percent.
A tank volume is 1200 m3 and flow is 2400 m3/day. HRT is what?
A 12 hours
B 6 hours
C 18 hours
D 24 hours
Answer: A. 12 hours. HRT = 1200/2400 day = 0.5 day, or 12 hours.
A population of 20,000 generates 80 L/person/day wastewater. Flow is what?
A 1.6 MLD
B 0.16 MLD
C 1.0 MLD
D 16 MLD
Answer: A. 1.6 MLD. 20,000 times 80 L/day equals 1,600,000 L/day, or 1.6 MLD.
A chlorine residual is 0.5 mg/L after a 2 mg/L dose. Demand is what?
A 0.5 mg/L
B 1.5 mg/L
C 2 mg/L
D 2.5 mg/L
Answer: B. 1.5 mg/L. Dose minus residual equals demand: 2.0 – 0.5 = 1.5 mg/L.
A 4 m wide channel carries 8 m3/s at 1 m depth. Mean velocity is what?
A 0.5 m/s
B 2 m/s
C 1 m/s
D 4 m/s
Answer: B. 2 m/s. Area = 4 times 1 = 4 m2; velocity = 8/4 = 2 m/s.
A 1000 m3/day flow has 10 percent peak factor. Peak flow is what?
A 1100 m3/day
B 100 m3/day
C 1000 m3/day
D 10,000 m3/day
Answer: A. 1100 m3/day. A 10 percent increase gives 1000 times 1.10 = 1100 m3/day.
A pump supplies 600 m3 in 3 hours. Average pumping rate is what?
A 180 m3/hour
B 200 m3/hour
C 300 m3/hour
D 600 m3/hour
Answer: B. 200 m3/hour. Rate = volume/time = 600/3 = 200 m3/hour.
A circular tank has area 50 m2 and water depth 4 m. Storage is what?
A 200 m3
B 54 m3
C 100 m3
D 400 m3
Answer: A. 200 m3. Volume = plan area times depth = 50 times 4 = 200 m3.