Staggered bolt holes can affect net area through…
A A zigzag failure path
B Concrete compression block
C Column base grout
D A weld throat only
Answer: A. A zigzag failure path. Net-section fracture may follow a staggered path; code provisions account for hole spacing and stagger.
Block shear resistance combines…
A Torsion and bending only
B Fatigue and creep only
C Shear planes and tension plane
D Bearing and buckling only
Answer: C. Shear planes and tension plane. Block shear is a connected block tearing along shear planes and a tension plane.
An eccentric bolt group must resist…
A Direct force and moment
B Only direct force
C Only temperature
D No shear demand
Answer: A. Direct force and moment. Eccentricity creates a moment in addition to the direct connection force.
A bolt in double shear has…
A One shear plane
B Two shear planes
C Three tension planes
D No shear plane
Answer: B. Two shear planes. A double-shear joint transfers force across two shear planes through the bolt.
Pretension in a slip-critical joint creates…
A A larger hole
B Weld metal
C Clamping friction
D Concrete bond
Answer: C. Clamping friction. Bolt pretension clamps the plies so friction resists service slip.
An eccentric weld group develops…
A Uniform force always
B No resultant moment
C Uneven weld force
D Only axial compression
Answer: C. Uneven weld force. Moment causes weld force to vary with location around the group.
Brittle fracture risk can rise with…
A Notches and low temperature
B Rounded smooth details
C High ductility
D Low stress concentration
Answer: A. Notches and low temperature. Stress raisers and low temperatures can reduce fracture resistance in susceptible steels.
Lamellar tearing is associated with…
A Beam lateral buckling
B Through-thickness strain
C Bolt slip only
D Column base bearing
Answer: B. Through-thickness strain. Weld shrinkage can cause tearing parallel to plate surfaces when through-thickness ductility is poor.
Repeated stress ranges primarily raise concern for…
A Fatigue cracking
B Local concrete crushing
C Creep only
D Thermal expansion only
Answer: A. Fatigue cracking. Cyclic stress can initiate and grow fatigue cracks at details.
Structural redundancy can improve…
A Corrosion resistance
B Steel yield stress
C Alternate load paths
D Weld penetration
Answer: C. Alternate load paths. Redundant systems may redistribute forces if a member loses capacity, subject to detailing.
A sharp re-entrant corner is undesirable because it…
A Raises net area
B Prevents fatigue
C Eliminates local buckling
D Concentrates stress
Answer: D. Concentrates stress. Abrupt geometry creates local stress concentrations.
Lateral bracing of a beam is placed to restrain…
A Tension-flange elongation
B Web shear only
C Support settlement
D Compression-flange movement
Answer: D. Compression-flange movement. Bracing limits lateral displacement and twist that can trigger lateral-torsional buckling.
Local buckling of a thin flange depends strongly on…
A Bolt count only
B Width-to-thickness ratio
C Paint thickness
D Span-to-depth ratio only
Answer: B. Width-to-thickness ratio. Plate slenderness controls susceptibility to local buckling.
A built-up column can fail by…
A Concrete punching only
B Slab vibration only
C Overall or component buckling
D Weld color change
Answer: C. Overall or component buckling. Built-up members require checks for overall buckling and behavior of components between connectors.
Lacing bars or battens must transfer…
A Shear between components
B Only paint load
C Water pressure
D Thermal radiation
Answer: A. Shear between components. Lacing or battens maintain composite action and transfer shear between built-up components.
A column base plate under compression transfers force through…
A Bearing to concrete
B Bolt friction only
C Weld throat only
D Soil tension only
Answer: A. Bearing to concrete. Base plate bearing spreads column compression into the concrete support.
Anchor rods are especially important when the base has…
A Compression only
B Tension or uplift
C No moment
D No shear
Answer: B. Tension or uplift. Anchor rods resist uplift and tension from overturning moment or direct tension.
A beam’s weaker bending axis is typically…
A Its major axis
B Its longitudinal axis
C Its minor axis
D Its shear center
Answer: C. Its minor axis. An I-section has much lower flexural stiffness about its minor axis.
A steel beam-column is checked for…
A Only bending
B Combined axial force and moment
C Only axial force
D Only torsion
Answer: B. Combined axial force and moment. Beam-columns carry axial force and bending, requiring interaction checks.
Welding can leave residual stress because of…
A Uniform room temperature
B Nonuniform heating and cooling
C Bolt pretension
D Concrete curing
Answer: B. Nonuniform heating and cooling. Localized heating and shrinkage create residual stresses in and around welds.
Fire protection for steel aims to…
A Increase member slenderness
B Remove bracing
C Increase corrosion
D Delay temperature rise
Answer: D. Delay temperature rise. Fire protection slows heating so steel retains strength longer during a fire.
A corrosion protection system needs…
A No access ever
B Unsealed crevices
C Wet coating only
D Inspection and maintenance
Answer: D. Inspection and maintenance. Coatings and protective systems need appropriate surface preparation, inspection and upkeep.
Ductile seismic steel connections need…
A Brittle fracture first
B Unbraced local buckling
C Unverified welds
D Stable inelastic deformation
Answer: D. Stable inelastic deformation. Ductile connections are detailed to sustain cyclic yielding without premature brittle failure.
Weld inspection can identify…
A Column slenderness
B Concrete cover
C Beam deflection only
D Cracks and lack of fusion
Answer: D. Cracks and lack of fusion. Visual and nondestructive inspection can detect surface or internal weld discontinuities.
A design review should trace…
A Loads through connections to supports
B Only member sizes
C Only paint specifications
D Only erection sequence
Answer: A. Loads through connections to supports. A complete load path carries forces through members and connections into the foundations.