Steel Structures MCQs (Set-1)

Structural steel is valued for…

A High strength and ductility
B Low stiffness only
C Brittle behavior only
D Zero maintenance needs

A tension member primarily carries…

A Bending only
B Compression only
C Axial pull
D Torsion only

A compression member can fail by…

A Only corrosion
B Buckling
C Thermal expansion
D Fatigue always

A steel beam primarily resists…

A Tension only
B Water pressure
C Thermal flow
D Bending and shear

A limit state design checks…

A Only appearance
B Only construction speed
C Only material cost
D Safety and serviceability

Gross area of a tension plate includes…

A Bolt holes only
B Entire cross-section
C Weld throat only
D Net ligament only

Net area deducts…

A Bolt holes and openings
B Edge distance
C Plate length
D Weld length only

A bolted connection transfers load through…

A Paint film only
B Concrete cover
C Surface drainage
D Bolt and connected plates

A fillet weld commonly joins surfaces meeting at…

A A single point
B No interface
C A circular bore only
D An angle

A butt weld joins members…

A At right angles only
B Through a pin
C In the same plane
D With no contact

A gusset plate commonly connects…

A Concrete slabs only
B Truss members at a joint
C Rail tracks only
D Column base grout

A tension member with bolt holes may fail by…

A Net-section rupture
B Concrete crushing
C Local foundation bearing
D Slab punching

Block shear failure combines…

A Bending and torsion only
B Buckling and fatigue only
C Tension and shear rupture
D Compression and bearing only

A slender steel column is sensitive to…

A Paint thickness only
B Bolt color
C Effective length and restraint
D Weld appearance

Lateral-torsional buckling affects…

A Tension rods only
B Unrestrained beam compression flange
C Concrete footings
D Bolted lap plates only

A lateral brace for a beam helps…

A Restrain compression flange
B Increase bolt holes
C Reduce steel grade
D Remove shear force

High-strength friction-grip bolts transfer shear mainly through…

A Friction between plates
B Bolt bearing only
C Weld metal
D Concrete bond

Bearing-type bolts transfer force after…

A Contact with hole surface
B Concrete curing
C Plate melting
D Frictionless separation

A snug-tight bolt is installed to…

A Melt the washer
B Create a weld
C Allow loose movement
D Bring plates into firm contact

A column base plate distributes…

A Water to roof drains
B Column load to foundation
C Traffic to pavement
D Beam load to slab only

A gusseted base often transfers…

A Only paint load
B Water flow
C Large column forces
D Floor vibration only

A beam-column connection may transfer…

A Only temperature
B Only surface water
C No structural force
D Shear and moment

Corrosion protection may include…

A Open drainage only
B Concrete aggregate
C Coatings or galvanizing
D Thermal expansion joints

Fire can reduce steel strength and stiffness by…

A Heating the member
B Cooling the member
C Increasing section area
D Closing bolt holes

A fatigue-sensitive steel detail should reduce…

A Member continuity
B Stress concentration
C Inspection access
D Load path clarity