Plant availability measures time a unit is what?
A Ready to operate
B At full load always
C Fuel free
D Under maintenance only
Answer: A. Ready to operate. Availability is the fraction of time the plant is capable of service.
Net electrical output equals gross generation minus what?
A Fuel energy
B Turbine speed
C Boiler pressure
D Auxiliary consumption
Answer: D. Auxiliary consumption. Net output subtracts station service loads from gross generator output.
Auxiliary power is consumed by pumps, fans and what?
A Plant equipment
B Grid customers
C Fuel chemical bonds
D Cooling water itself
Answer: A. Plant equipment. Station auxiliaries include pumps, fans, mills and other operating equipment.
Specific fuel consumption is fuel used per unit what?
A Boiler area
B Electrical output
C Cooling tower height
D Steam pressure
Answer: B. Electrical output. Specific fuel consumption relates fuel mass to generated electrical energy.
A lower heat rate generally indicates what?
A Lower output voltage
B Higher efficiency
C Higher fuel use
D More condenser leakage
Answer: B. Higher efficiency. Heat rate is inversely related to plant thermal efficiency.
Condenser back pressure rises if cooling water becomes what?
A Colder
B More pure
C More pressurized only
D Warmer
Answer: D. Warmer. Warmer cooling water reduces heat-rejection driving force and tends to raise back pressure.
Cooling tower approach is cold-water temperature minus what?
A Entering wet-bulb temperature
B Dry-bulb temperature
C Steam temperature
D Condenser pressure
Answer: A. Entering wet-bulb temperature. Approach is the cold-water outlet temperature above ambient wet-bulb temperature.
Bottom ash and fly ash are products of what fuel?
A Nuclear fission
B Hydraulic generation
C Solar heating
D Coal combustion
Answer: D. Coal combustion. Coal combustion leaves ash as bottom ash and fly ash.
Boiler blowdown controls buildup of what in water?
A Dissolved solids
B Turbine speed
C Air humidity
D Fuel sulfur
Answer: A. Dissolved solids. Blowdown removes concentrated boiler water to limit dissolved solids and deposits.
Water treatment helps prevent scale and what?
A Turbine overspeed
B Generator slip
C Fuel knock
D Corrosion
Answer: D. Corrosion. Proper water chemistry minimizes scale, corrosion and carryover.
Scale on boiler tubes adds what thermal effect?
A Insulating resistance
B Enhanced conductivity
C More steam pressure
D Lower tube temperature drop
Answer: A. Insulating resistance. Scale has low conductivity and impedes heat transfer to water.
Dissolved oxygen in feedwater promotes what?
A Combustion stability
B Turbine efficiency
C Water head
D Corrosion
Answer: D. Corrosion. Oxygen attacks steel and can cause corrosion in feedwater and boiler systems.
A supercritical boiler operates above water’s what pressure?
A Atmospheric pressure
B Critical pressure
C Condenser pressure
D Triple-point pressure
Answer: B. Critical pressure. Above the critical pressure, liquid and vapor phases are no longer distinct.
A reheater receives steam from which turbine section?
A Condenser outlet
B Feed pump discharge
C High-pressure turbine exhaust
D Boiler fuel bed
Answer: C. High-pressure turbine exhaust. Steam leaving the high-pressure turbine is reheated before later expansion stages.
A boiler safety valve opens when pressure exceeds what?
A Atmospheric pressure only
B Condenser pressure
C Set limit
D Feed pump head
Answer: C. Set limit. A safety valve relieves steam when pressure exceeds its calibrated set point.
Black-start capability means a plant can start without what?
A External grid supply
B Fuel
C Cooling water
D Control system
Answer: A. External grid supply. A black-start unit can start and energize systems without grid power.
A forced outage occurs due to what?
A Scheduled maintenance
B Normal dispatch
C Unplanned failure
D Fuel procurement plan
Answer: C. Unplanned failure. Forced outages are unplanned removals from service due to faults or failures.
The diversity factor is sum of individual peaks divided by what?
A Average system load
B Installed generation
C Fuel input
D Coincident system peak
Answer: D. Coincident system peak. Diversity factor compares noncoincident individual maxima with the coincident maximum demand.
Utilization factor compares maximum demand with what?
A Average load
B Rated capacity
C Minimum load
D Fuel heating value
Answer: B. Rated capacity. Utilization factor is maximum demand divided by rated capacity.
A plant reserve margin compares capacity above peak with what?
A Average voltage
B Fuel supply
C Peak demand
D Cooling load
Answer: C. Peak demand. Reserve margin is installed capacity above peak demand, expressed relative to peak demand.
Combined-cycle efficiency benefits from recovering what?
A Condenser vacuum
B Gas-turbine exhaust heat
C Cooling tower drift
D Ash heat only
Answer: B. Gas-turbine exhaust heat. The bottoming steam cycle uses exhaust heat that would otherwise be rejected.
A flue-gas stack primarily discharges treated what?
A Feedwater
B Steam condensate
C Combustion products
D Cooling water
Answer: C. Combustion products. The stack releases cleaned flue gas at a height for dispersion.
A thermal power plant can reduce particulate emissions using what?
A Feedwater pump
B Economizer
C Baghouse filter
D Deaerator
Answer: C. Baghouse filter. A fabric filter or baghouse captures particles from flue gas.
Excess combustion air means air above what requirement?
A Cooling air
B Stoichiometric air
C Turbine flow
D Condenser duty
Answer: B. Stoichiometric air. Excess air is supplied beyond the theoretical amount needed for complete combustion.
A cooling-water treatment program controls scale, corrosion and what?
A Biological growth
B Turbine power
C Grid frequency
D Fuel octane
Answer: A. Biological growth. Cooling circuits require control of deposits, corrosion and biological fouling.