A power plant primarily converts primary energy into what?
A Chemical energy only
B Fluid pressure only
C Mechanical energy only
D Electrical energy
Answer: D. Electrical energy. A power plant converts an energy source into electrical output.
A conventional steam station commonly follows which cycle?
A Rankine cycle
B Otto cycle
C Diesel cycle
D Brayton cycle
Answer: A. Rankine cycle. The Rankine cycle models steam power plants with boiler, turbine, condenser and pump.
A boiler adds heat to produce what working fluid?
A Steam
B Compressed air
C Liquid fuel
D Cooling water only
Answer: A. Steam. The boiler transfers heat to feedwater and produces steam.
A superheater raises steam temperature above what?
A Critical pressure
B Condenser temperature
C Saturation temperature
D Feedwater temperature always
Answer: C. Saturation temperature. A superheater adds sensible heat to saturated or wet steam.
An economizer preheats which stream using flue gas?
A Cooling water
B Fuel oil
C Feedwater
D Turbine exhaust
Answer: C. Feedwater. An economizer recovers flue-gas heat to warm boiler feedwater.
An air preheater transfers flue-gas heat to what?
A Condensate
B Combustion air
C Turbine oil
D Ash slurry
Answer: B. Combustion air. An air preheater warms incoming combustion air using exhaust gas.
A steam turbine converts steam energy into what?
A Shaft work
B Fuel pressure
C Electrical charge directly
D Cooling capacity
Answer: A. Shaft work. The turbine expands steam to produce shaft power.
A condenser changes turbine exhaust steam into what?
A Liquid water
B Superheated steam
C Combustion gas
D Compressed air
Answer: A. Liquid water. The condenser rejects heat and condenses low-pressure exhaust steam.
A boiler feed pump raises what?
A Steam quality
B Flue-gas temperature
C Coal particle size
D Feedwater pressure
Answer: D. Feedwater pressure. The feed pump raises condensate pressure before it enters the boiler.
A deaerator removes dissolved gases from what?
A Flue gas
B Coal ash
C Turbine steam only
D Feedwater
Answer: D. Feedwater. Deaeration removes oxygen and other dissolved gases that promote corrosion.
A cooling tower rejects heat mainly by what process?
A Combustion
B Compression
C Electrical resistance
D Evaporation
Answer: D. Evaporation. Evaporating a small fraction of cooling water removes heat from the rest.
A natural-draft cooling tower uses what to move air?
A Density difference
B Steam turbine
C Water pump only
D Fuel pressure
Answer: A. Density difference. Warm moist air rises and induces airflow through a natural-draft tower.
A forced-draft fan pushes air into what?
A Condenser shell
B Boiler or furnace
C Turbine casing
D Feedwater tank
Answer: B. Boiler or furnace. A forced-draft fan supplies combustion air by pushing it into the furnace.
An induced-draft fan pulls flue gas through what?
A Feedwater circuit
B Steam turbine
C Boiler gas path
D Cooling tower basin
Answer: C. Boiler gas path. An induced-draft fan draws combustion products through the boiler and toward the stack.
Pulverized-coal firing burns coal in what form?
A Large blocks
B Liquid slurry only
C Fine particles
D Compressed pellets only
Answer: C. Fine particles. Fine coal particles burn rapidly while suspended in the furnace.
Boiler efficiency compares useful steam heat with what input?
A Fuel energy
B Turbine output only
C Cooling-water mass
D Ash weight
Answer: A. Fuel energy. Boiler efficiency is useful heat absorbed by working fluid divided by fuel energy input.
Combustion efficiency is improved by adequate air and what?
A Cold furnace walls
B Good mixing
C High ash content
D Low fuel contact
Answer: B. Good mixing. Effective combustion needs suitable air supply, mixing, temperature and residence time.
Reheat in a steam cycle reduces what at turbine exhaust?
A Condenser pressure
B Pump work to zero
C Moisture content
D Feedwater mass
Answer: C. Moisture content. Reheating steam between turbine stages increases exhaust quality and can improve efficiency.
Regenerative feedwater heating uses steam extraction to do what?
A Cool the boiler
B Increase condenser heat loss
C Dry coal
D Warm feedwater
Answer: D. Warm feedwater. Bleed steam heats feedwater and raises average heat-addition temperature.
Condenser pressure reduction generally increases what?
A Pump work greatly
B Turbine work
C Boiler pressure loss
D Feedwater oxygen
Answer: B. Turbine work. Lower exhaust pressure increases turbine expansion and specific work.
A high condenser vacuum corresponds to what absolute pressure?
A High pressure
B Low pressure
C Atmospheric pressure only
D Zero temperature
Answer: B. Low pressure. A strong vacuum means condenser absolute pressure is well below atmospheric pressure.
Plant heat rate is fuel energy divided by what output?
A Electrical energy
B Cooling-water flow
C Steam pressure
D Turbine mass
Answer: A. Electrical energy. Heat rate is the fuel energy input required per unit of electrical generation.
Thermal efficiency is net work divided by what?
A Heat rejected
B Steam mass
C Heat supplied
D Condenser area
Answer: C. Heat supplied. Thermal efficiency compares useful cycle work with heat input.
A safety valve protects a boiler from what?
A Low feedwater temperature
B Overpressure
C High ash content
D Low turbine speed
Answer: B. Overpressure. The safety valve opens to limit excessive boiler pressure.
Steam-cycle condensate returns to the boiler as what?
A Fuel
B Flue gas
C Ash
D Feedwater
Answer: D. Feedwater. Condensate is pumped and treated before returning as boiler feedwater.