Metrology is the science of what?
A Machining
B Measurement
C Welding
D Casting
Answer: B. Measurement. Metrology covers measurement, standards, calibration and uncertainty.
A measurement compares an unknown quantity with what?
A A drawing only
B A standard
C A machine bed
D A work schedule
Answer: B. A standard. Measurement assigns a value by comparison with an agreed unit or standard.
Accuracy describes closeness to what value?
A Repeated value
B Display resolution
C True value
D Nominal size only
Answer: C. True value. Accuracy is closeness of a result to the accepted reference value.
Precision describes agreement among what?
A Repeated measurements
B True and nominal values
C Two standards
D Different units
Answer: A. Repeated measurements. Precision is the closeness of repeated measurements to one another.
Resolution is the smallest change an instrument can what?
A Display or detect
B Calibrate automatically
C Correct for drift
D Measure without error
Answer: A. Display or detect. Resolution is the smallest input increment that produces a discernible output change.
Sensitivity is output change divided by what?
A Input change
B Measurement error
C Calibration interval
D Standard uncertainty
Answer: A. Input change. Sensitivity is the ratio of instrument output change to input change.
Calibration compares an instrument with what?
A Production schedule
B Machine tool
C Reference standard
D Finished product only
Answer: C. Reference standard. Calibration determines instrument indication relative to a known reference.
Metrological traceability uses an unbroken chain of what?
A Production steps
B Operator approvals
C Calibrations to standards
D Inspection samples
Answer: C. Calibrations to standards. Traceability links a measurement result to references through documented calibrations.
Measurement error is measured value minus what?
A Resolution
B Reference value
C Tolerance
D Standard deviation
Answer: B. Reference value. Error is the difference between a measured result and the reference value.
A systematic error tends to be what across repeats?
A Consistent bias
B Randomly changing sign
C Exactly zero
D Equal to resolution
Answer: A. Consistent bias. Systematic error shifts measurements in a consistent direction or pattern.
Random error varies how between repeated readings?
A In one fixed direction
B By a fixed constant
C Only with units
D Unpredictably
Answer: D. Unpredictably. Random error fluctuates from reading to reading.
A gross measurement error may result from what?
A Stable calibration
B Correct zeroing
C Known resolution
D Operator mistake
Answer: D. Operator mistake. Gross errors can arise from misreading, recording or setup mistakes.
Least count is the smallest scale division an instrument can what?
A Amplify
B Calibrate
C Correct automatically
D Read directly
Answer: D. Read directly. Least count is the smallest direct reading increment of an instrument scale.
A vernier caliper can measure external, internal and what dimension?
A Depth
B Torque
C Surface temperature
D Electrical resistance
Answer: A. Depth. A vernier caliper commonly measures outside, inside and depth dimensions.
A micrometer screw gauge converts rotation into what?
A Linear displacement
B Angular velocity
C Pressure
D Temperature
Answer: A. Linear displacement. The screw mechanism produces a small linear spindle movement from rotation.
Micrometer pitch is spindle travel per what?
A One scale division
B One revolution
C One measurement
D One millimetre always
Answer: B. One revolution. Screw pitch is the axial movement for one complete screw rotation.
Zero error exists when an unloaded instrument indicates what?
A Nonzero reading
B Perfect zero
C Maximum range
D Reference length
Answer: A. Nonzero reading. Zero error is a nonzero indication when the measured quantity should be zero.
Parallax error occurs when a scale is viewed from what?
A Normal angle
B Behind a mirror
C Oblique angle
D Under calibration
Answer: C. Oblique angle. Viewing a scale from an angle shifts the apparent pointer position.
Gauge blocks are precision standards of what?
A Known mass
B Known length
C Known pressure
D Known temperature
Answer: B. Known length. Gauge blocks provide accurate length standards for dimensional measurement.
A comparator indicates deviation from what?
A Absolute mass
B Surface temperature
C Tool speed
D Master dimension
Answer: D. Master dimension. Comparators magnify dimensional difference from a reference or master.
A dial indicator converts plunger travel into what display?
A Digital temperature
B Electrical resistance
C Fluid pressure
D Pointer rotation
Answer: D. Pointer rotation. A rack-and-pinion mechanism converts small plunger displacement into pointer movement.
A height gauge measures vertical dimensions from what?
A Machine spindle
B Workpiece axis only
C Surface plate
D Tool tip only
Answer: C. Surface plate. A height gauge references a surface plate to measure vertical distances.
A depth gauge measures distance below what?
A Centerline
B Pitch circle
C Datum axis only
D Reference surface
Answer: D. Reference surface. A depth gauge measures recesses or holes relative to a reference face.
Wringing gauge blocks uses what effect?
A Magnetic force only
B Molecular attraction
C Vacuum pressure
D Thermal expansion
Answer: B. Molecular attraction. Clean gauge blocks adhere by molecular attraction and surface effects.
An end standard defines length between what?
A Scale markings
B Laser spots
C Two end faces
D Pointer readings
Answer: C. Two end faces. Gauge blocks are end standards whose length is defined between parallel measuring faces.