What is the main role of a foundation?
A Increase roof area
B Reduce concrete curing
C Transfer loads to ground
D Support electrical wiring
Answer: C. Transfer loads to ground. A foundation transfers structural actions safely into supporting soil or rock.
A shallow foundation transfers load mainly near what?
A Deep rock only
B A distant pile group
C Ground surface
D A buried tunnel
Answer: C. Ground surface. Shallow footings spread loads to soil close to the ground surface.
Which footing commonly supports one column?
A Isolated footing
B Strip footing
C Raft foundation
D Sheet pile
Answer: A. Isolated footing. An isolated footing supports a single column or pedestal.
A continuous wall is commonly supported by which foundation?
A Pile cap
B Strip footing
C Caisson
D Isolated pad
Answer: B. Strip footing. A strip footing distributes wall loads along a continuous narrow base.
A combined footing is useful when columns are what?
A At different buildings
B Only on rock
C Outside the site
D Close together
Answer: D. Close together. A combined footing supports two or more columns when separate pads would overlap or be unsuitable.
A strap beam commonly connects which foundations?
A A pile and caisson
B Two retaining walls
C A roof and slab
D Two column footings
Answer: D. Two column footings. A strap beam links eccentric and interior column footings to balance load effects.
A raft foundation supports columns using what element?
A Large continuous slab
B Single small pad
C Timber wall
D Narrow pile shaft
Answer: A. Large continuous slab. A raft or mat spreads many column or wall loads over a large area.
Pile foundations are classified as what type?
A Shallow foundations
B Deep foundations
C Ground anchors only
D Surface slabs
Answer: B. Deep foundations. Piles transfer load through deeper soil layers and are deep foundations.
A pile can transfer load through shaft friction and what?
A Capillary rise
B End bearing
C Wall adhesion
D Roof bracing
Answer: B. End bearing. Axial pile resistance can come from shaft resistance and toe or end bearing.
A caisson is a foundation often used for what?
A Light partition walls
B Roof trusses
C Shallow floor tiles
D Bridge piers in water
Answer: D. Bridge piers in water. Caissons can provide deep support for bridge piers and other structures in water or difficult ground.
Ultimate bearing capacity is the pressure at what state?
A Foundation shear failure
B Zero settlement
C Full saturation
D Minimum compaction
Answer: A. Foundation shear failure. Ultimate bearing capacity is associated with failure of the supporting soil.
Allowable bearing pressure is limited by bearing failure and what?
A Permissible settlement
B Concrete color
C Column slenderness only
D Water content alone
Answer: A. Permissible settlement. Design pressure must satisfy both strength and serviceability settlement limits.
Which field test measures penetration resistance with a cone?
A CPT
B SPT
C Plate load test
D Vane shear test
Answer: A. CPT. A cone penetration test pushes an instrumented cone into the ground and measures resistance.
The standard penetration test uses which sampler?
A Thin plate sampler
B Concrete core barrel
C Hydrometer jar
D Split-spoon sampler
Answer: D. Split-spoon sampler. SPT drives a split-spoon sampler and records penetration resistance.
A plate load test primarily observes pressure versus what?
A Water content
B Pile torque
C Settlement
D Soil color
Answer: C. Settlement. The test applies load to a plate and measures resulting settlement.
Immediate foundation settlement is often associated with what response?
A Long-term creep only
B Concrete shrinkage
C Elastic soil deformation
D Pile corrosion
Answer: C. Elastic soil deformation. Immediate settlement occurs soon after loading through elastic or near-elastic soil deformation.
Consolidation settlement is especially important in which soil?
A Dry gravel
B Saturated clay
C Sound granite
D Steel slag
Answer: B. Saturated clay. Low-permeability saturated clay may consolidate over time as excess pore pressure dissipates.
Differential settlement means what?
A Uniform site uplift
B No foundation movement
C Unequal movement across supports
D Only lateral sliding
Answer: C. Unequal movement across supports. Differential settlement is a difference in vertical movement between foundation points.
A shallow footing should be founded below what vulnerable layer?
A Sound bearing stratum
B All compacted sand
C Every groundwater zone
D Topsoil and fill
Answer: D. Topsoil and fill. Topsoil and uncontrolled fill are usually unsuitable bearing layers and are removed or bypassed.
Groundwater near a footing can reduce effective what?
A Concrete strength
B Column load
C Footing width
D Soil stress
Answer: D. Soil stress. High groundwater increases pore pressure and can reduce effective stress and bearing resistance.
The bearing capacity factor Nc is associated with which soil property?
A Cohesion
B Permeability
C Specific gravity
D Water content
Answer: A. Cohesion. In classic bearing-capacity equations, the cohesion term is multiplied by Nc.
The factor Nq multiplies which pressure term?
A Concrete unit weight
B Surcharge at footing level
C Pile shaft area
D Water content
Answer: B. Surcharge at footing level. The surcharge contribution in bearing capacity is q Nq.
An under-reamed pile has what feature?
A Hollow steel cap
B Surface-only slab
C Enlarged bulb near base
D No toe resistance
Answer: C. Enlarged bulb near base. Under-reamed piles include one or more enlarged bulbs, commonly used in expansive soils.
A pile cap distributes column load to what elements?
A Pile group
B Soil nails
C Roof beams
D Retaining wall drains
Answer: A. Pile group. A pile cap transfers superstructure forces into the supporting piles.
Foundation selection should consider soil profile and what else?
A Paint color
B Structural loads
C Interior lighting
D Road markings
Answer: B. Structural loads. A suitable foundation reflects ground conditions, load magnitude, settlement tolerance and construction constraints.