Fibre Science MCQs (Set-4)

Difficulty: Hard

Why can one micronaire value not separate fineness from maturity?

A Both affect airflow
B Only length affects airflow
C Colour masks fineness
D Crimp sets the reading

How can bundle strength differ from mean single-fibre strength?

A Single fibres contain dye
B Bundles remove all variation
C Load sharing differs
D Bundle fibres have no length

Changing tensile gauge length can alter which result?

A Strength distribution
B Moisture regain formula
C Fibre polymer identity
D Cross-section chemistry

Two fibres break at equal force; which has higher tenacity?

A Higher linear density
B Lower linear density
C Greater moisture content
D Longer staple only

The initial modulus comes from which curve feature?

A Initial stress-strain slope
B Maximum fibre length
C Area under curve
D Curve endpoint only

Work to rupture corresponds to what?

A Micronaire reading
B Peak colour value
C Fibre count per gram
D Area under load-extension curve

With constant mean length, what happens when SD rises?

A CV increases
B CV decreases
C Mean doubles
D Length becomes uniform

Name the composite airflow measure used for cotton.

A Fibre aspect ratio
B Micronaire
C Staple length
D Single-fibre modulus

What is the purpose of moisture conditioning?

A Straighten every crimp
B Reach moisture equilibrium
C Remove all fibre defects
D Increase sample mass permanently

Which denominator distinguishes regain from content?

A Dry versus conditioned mass
B Length versus diameter
C Force versus extension
D Mean versus deviation

Which property can projection microscopy measure?

A Fabric abrasion loss
B Dye bath pH
C Yarn twist direction
D Fibre diameter

HVI length analysis uses which specimen form?

A Prepared fibre beard
B Loose staple bale
C Woven fabric strip
D Twisted yarn loop

Mean length is 20 mm and upper-half mean is 25 mm. Find uniformity index.

A 45 percent
B 100 percent
C 80 percent
D 125 percent

For a dry mass of 50 g at 8% regain, how much water is present?

A 8 g
B 54 g
C 2 g
D 4 g

Four grams of water are in a 54 g conditioned sample. Find moisture content.

A 50 percent
B 7.4 percent
C 8 percent
D 12.5 percent

For a fixed fibre material, higher linear density usually means what?

A Shorter molecular chains
B Lower polymer density
C Less fibre mass per length
D Larger cross-section

If density is fixed, linear density varies with which quantity?

A Crimp frequency only
B Gauge length
C Cross-sectional area
D Fibre colour

What should a fibre report include to describe spread?

A One selected fibre
B Maximum alone
C Colour alone
D Mean and variability

Repeated tests under unchanged conditions estimate what?

A Reproducibility
B Fineness
C Repeatability
D Maturity

Comparable tests across different laboratories assess what?

A Staple length
B Moisture regain
C Reproducibility
D Repeatability only

Reference weights are used to verify what?

A Count cotton neps
B Measure fibre maturity
C Set yarn twist
D Check force calibration

What should happen after a jaw break?

A Report full gauge strength
B Double the specimen length
C Treat result as invalid
D Average without review

Because specimen size affects force, which two results should be reported?

A Force measures maturity
B Size affects breaking force
C Both are always identical
D Tenacity measures colour

Which statistic is most sensitive to a few extreme lengths?

A Lower quartile
B Range
C Median
D Mode

What does a low short-fibre index generally suggest?

A More trash particles
B Higher moisture regain
C Fewer short fibres
D Lower polymer density