Answer: D. 2.5 V. Equal resistors divide the input voltage equally, giving 2.5 V at the midpoint.
What happens to an NTC thermistorβs resistance as temperature rises?
A It increases
B It stays fixed
C It decreases
D It becomes infinite
Answer: C. It decreases. A negative-temperature-coefficient thermistor has lower resistance at higher temperature.
A PTC thermistor generally changes resistance how as temperature rises?
A It decreases
B It increases
C It stays fixed
D It becomes zero
Answer: B. It increases. A positive-temperature-coefficient thermistorβs resistance rises with temperature over its operating range.
A 12 V actuator receives 25% PWM duty cycle. Ideal average voltage is what?
A 6 V
B 3 V
C 9 V
D 12 V
Answer: B. 3 V. For an ideal switched resistive load, average voltage is supply voltage Γ duty cycle: 12 Γ 0.25 = 3 V.
A signal contains frequencies up to 100 Hz. What minimum sample rate avoids basic aliasing?
A 100 samples/s
B 50 samples/s
C 200 samples/s
D 1,000 samples/s
Answer: C. 200 samples/s. The Nyquist criterion requires sampling at more than twice the highest signal frequency.
What does a low-pass filter attenuate?
A High-frequency noise
B DC supply voltage
C All sensor signals
D Mechanical vibration only
Answer: A. High-frequency noise. A low-pass filter passes slower signal changes while reducing higher-frequency components.
A linear sensor changes 0.5 V for every 10Β°C. What is its sensitivity?
A 0.5 V/Β°C
B 0.05 V/Β°C
C 5 V/Β°C
D 20 V/Β°C
Answer: B. 0.05 V/Β°C. Sensitivity is output change divided by input change: 0.5/10 = 0.05 V per degree Celsius.
Why use an instrumentation amplifier with a low-level sensor?
A Changes tire pressure
B Measures engine speed
C Opens CAN bus
D Amplifies differential signal
Answer: D. Amplifies differential signal. An instrumentation amplifier boosts a small differential sensor signal while rejecting common-mode voltage.
What does a CAN frameβs CRC help detect?
A Low tire pressure
B Data transmission errors
C Wrong fuel grade
D Weak spring force
Answer: B. Data transmission errors. The cyclic redundancy check helps the receiver detect corruption in a transmitted frame.
What does a pull-up resistor do for a switch input?
A Raises engine torque
B Filters fuel vapor
C Defines a default logic level
D Changes sensor temperature
Answer: C. Defines a default logic level. A pull-up holds a digital input at a known logic level when the switch is open.
How does a low-side driver switch a load?
A Connects load to battery positive
B Changes the sensor range
C Connects load toward ground
D Opens the CAN pair
Answer: C. Connects load toward ground. A low-side driver controls current by switching the loadβs return path to ground.
What does a high-side driver switch?
A Ground-only connection
B Sensor calibration value
C CAN message priority
D Supply-side connection
Answer: D. Supply-side connection. A high-side driver controls current by switching the positive supply path to a load.
What does an H-bridge allow an ECU to control?
A Sensor resistance
B Battery chemistry
C CAN termination
D Motor direction
Answer: D. Motor direction. An H-bridge reverses current through a motor so it can rotate in either direction.
Why add dead time between complementary motor-driver switches?
A Prevent shoot-through current
B Increase battery capacity
C Raise PWM frequency
D Change sensor offset
Answer: A. Prevent shoot-through current. Brief dead time prevents both switches in one bridge leg from conducting at once and shorting the supply.
What does proportional control respond to?
A Stored fault count
B Current control error
C Battery age
D Tire wear
Answer: B. Current control error. A proportional controller changes its output in proportion to the present difference between target and measured value.
Which PID term can remove steady-state offset?
A Integral term
B Proportional term only
C Derivative term only
D CAN checksum
Answer: A. Integral term. Integral action accumulates error over time and can eliminate persistent steady-state offset.
Which PID term responds to error changing rate?
A Integral term
B Proportional term
C Feed fuse
D Derivative term
Answer: D. Derivative term. Derivative action responds to the rate of change of error and can add damping to the response.
Why can a noisy sensor need filtering before control?
A Avoid false rapid corrections
B Increase wheel torque
C Change battery capacity
D Raise sampling error
Answer: A. Avoid false rapid corrections. Filtering reduces noise that could otherwise cause unnecessary or unstable actuator commands.
What does a sample-and-hold circuit do before ADC conversion?
A Stabilizes input voltage
B Raises sensor resistance
C Stores all trip records
D Changes bus topology
Answer: A. Stabilizes input voltage. A sample-and-hold circuit captures an input voltage and holds it steady while the converter performs a measurement.
Why can a sensor ground offset distort a reading?
A CAN arbitration improves
B Reference voltage shifts
C ADC bits increase
D Actuator force doubles
Answer: B. Reference voltage shifts. Voltage measured relative to a shifted ground no longer represents the intended sensor signal.
A sensor output changes 2.0 V over 40 units. What is average sensitivity?
A 0.5 V per unit
B 20 V per unit
C 0.05 V per unit
D 80 V per unit
Answer: C. 0.05 V per unit. Average sensitivity is output change divided by input change: 2/40 = 0.05 V per unit.
Why does a sensor calibration table map raw codes to physical units?
A Convert signal to measurement
B Increase ADC voltage
C Replace the sensor
D Set CAN arbitration
Answer: A. Convert signal to measurement. Calibration maps measured electrical values to engineering quantities such as temperature or pressure.
What can a diagnostic open-circuit bias help an ECU identify?
A Excessive tire grip
B Low engine compression
C Wrong wheelbase
D Disconnected sensor wiring
Answer: D. Disconnected sensor wiring. A designed bias voltage can make an open sensor circuit produce a detectable out-of-range input.
Why should actuator current be monitored by a driver circuit?
A Detect open or short faults
B Increase sensor resolution
C Change ECU clock speed
D Reduce wheelbase
Answer: A. Detect open or short faults. Current monitoring can help detect a disconnected load, short circuit, or actuator fault.