Reinforced Concrete Structures MCQs (Set-4)

Capacity design in seismic frames generally favors…

A Beam hinging before columns
B Column hinging first
C Joint shear failure
D Brittle bar pullout

Lap splices in seismic columns should avoid…

A Low-moment midheight only
B Straight bar lengths
C Potential hinge regions
D Protected joint zones

Confinement ties in a column plastic hinge region should be…

A Closely spaced
B Omitted completely
C Widely spaced
D Only at midheight

Joint shear demand is high because…

A Concrete has no weight
B Columns carry no load
C Beam forces enter the joint
D The slab is unloaded

A slab-column connection under a large concentrated load needs checking for…

A Only flexural cracking
B Punching shear
C Only column buckling
D Only bar corrosion

A deep beam’s load path is often represented by…

A Uniform flexure only
B Pure torsion loops
C A cable net only
D Compression struts and tension ties

Closed stirrups are important for beam torsion because they…

A Carry only axial compression
B Form a closed shear-flow path
C Prevent all cracking
D Replace longitudinal bars

Distribution reinforcement in slabs helps control…

A Crack width and shrinkage
B Column axial capacity
C Footing bearing
D Concrete density

A beam bar continuing into a support needs…

A No embedment
B Only a paint coating
C An unrestrained end
D Adequate anchorage

Development length increases when bar stress demand…

A Falls to zero
B Has no relation
C Becomes compressive only
D Increases

Bar spacing must allow…

A Aggregate blockage
B Vibrator exclusion
C Concrete flow and compaction
D Cover removal

Required cover is influenced by…

A Only beam length
B Exposure and fire requirements
C Only bar count
D Only concrete color

Chloride ingress can promote…

A Steel yielding strength
B Concrete hydration
C Aggregate interlock
D Reinforcement corrosion

Carbonation threatens reinforcement by…

A Increasing bar diameter
B Stopping all moisture
C Reducing concrete alkalinity
D Raising steel yield stress

Fire resistance of an RC member depends partly on…

A Cover and member dimensions
B Only aggregate color
C Only beam support type
D Only bar grade

For a slab supported on four sides, a large long-to-short ratio favors…

A Equal two-way action
B Pure torsion
C One-way action
D No bending

A flat slab connection must consider unbalanced…

A Moment transfer
B Aggregate size
C Floor finish color
D Curing water only

A column design under axial load and bending uses…

A Shear-span ratio only
B P-M interaction
C Concrete slump
D Bar spacing only

Second-order column moments are amplified by…

A Concrete cover
B Bar bond only
C Curing time
D Lateral deflection under axial load

A brittle shear failure is undesirable because it is…

A Sudden with little warning
B Highly ductile
C Always reversible
D A serviceability limit only

Diagonal shear cracking is controlled with…

A Transverse reinforcement
B Only top longitudinal bars
C Surface coating
D Curing compound

Serviceability checks are distinct from collapse checks because they address…

A Only ultimate strength
B Use and comfort
C Only footing size
D Only construction cost

Durability detailing should reduce…

A Steel area
B Water and chloride ingress
C Concrete strength
D Aggregate interlock

A beam-column joint detail must provide…

A Unanchored bars
B Open transverse ties
C No concrete consolidation
D Force transfer and confinement

Before approving an RC design, verify…

A Only analysis output
B Only bar diameter
C Load path and detailing
D Only concrete grade