A sample has Cq 18 and a calibrator has Cq 23 for the same assay. Assuming near-perfect efficiency and comparable conditions, approximately how much more target did the sample start with?
A 5-fold
B 10-fold
C 16-fold
D 32-fold
Answer: D. 32-fold. A five-cycle difference corresponds to about 2⁵, or 32-fold, at ideal efficiency.
A qPCR study compares two genes using ΔΔCq. Which assumption is important for the simple calculation?
A Target and reference assays have suitably similar amplification efficiencies
B Both genes must encode proteins of the same length
C The no-template control must amplify
D The samples must have identical fluorescence colors
Answer: A. Target and reference assays have suitably similar amplification efficiencies. The comparative Cq method assumes sufficiently similar and validated amplification efficiencies.
An NTC develops a late amplification curve with a low-temperature melt peak, while samples show the expected higher-temperature peak. Which interpretation best fits?
A The NTC proves the samples are contaminated with target
B Likely primer-dimer signal in the NTC rather than the intended amplicon
C The samples contain no PCR product
D The positive control failed
Answer: B. Likely primer-dimer signal in the NTC rather than the intended amplicon. A low-melting late NTC product often reflects primer dimers, though controls and assay criteria still matter.
A PCR assay detects a pathogen target, but the extraction control fails. How should the sample result be treated?
A As definitively positive
B As definitively negative
C As potentially invalid because successful extraction was not demonstrated
D As proof that the target mutated
Answer: C. As potentially invalid because successful extraction was not demonstrated. A failed extraction control undermines confidence that the sample was processed successfully.
After 30 ideal cycles from one starting DNA molecule, how many copies are predicted before accounting for real-world limits?
A 30 copies
B 30²
C 2 × 30
D 2³⁰
Answer: D. 2³⁰. Perfect doubling predicts 2³⁰ copies, although practical reactions do not maintain ideal efficiency throughout.
A researcher needs to distinguish two products that differ by only 8 bp near 100 bp. Which change is most likely to improve resolution?
A Use a higher-percentage agarose gel or an appropriate high-resolution gel system
B Use a much lower-percentage gel
C Add more template until the wells overflow
D Replace DNA stain with antibody
Answer: A. Use a higher-percentage agarose gel or an appropriate high-resolution gel system. Higher-percentage or specialized gels can better resolve small fragments with close sizes.
A PCR amplicon is much longer than the usual range for the selected polymerase. Which strategy is most appropriate?
A Shorten extension time to avoid errors
B Use a polymerase and extension program validated for long amplicons
C Remove one primer
D Replace dNTPs with ddNTPs
Answer: B. Use a polymerase and extension program validated for long amplicons. Long-range amplification requires suitable enzyme properties and adequate extension conditions.
In endpoint PCR, sample A has a brighter band than sample B after many cycles. Why is this not automatically a reliable fold-change estimate?
A PCR never amplifies DNA exponentially
B The bands are proteins
C Both reactions may have reached different or similar plateaus
D Agarose cannot separate DNA
Answer: C. Both reactions may have reached different or similar plateaus. Endpoint yield after many cycles is affected by plateau behavior and may not track initial amount proportionally.
A probe-based qPCR assay produces fluorescence but the melt-curve check is unavailable. Which control remains important for detecting reagent contamination?
A Restriction digest of the product only
B Protein ladder
C No-primary-antibody control
D No-template control
Answer: D. No-template control. The NTC indicates whether amplification signal can arise without sample template.
A researcher designs one primer across a splice junction, but the junction lies too close to the primer’s 5′ end. What should be improved?
A Place the junction nearer the extendable 3′ end or use another validated design
B Move the primer entirely outside the transcript
C Remove the reverse primer
D Increase the DNA ladder concentration
Answer: A. Place the junction nearer the extendable 3′ end or use another validated design. A junction near the 3′ end can better discriminate cDNA from genomic DNA during extension.
A variant is detected by allele-specific PCR only when a 3′-matched primer is used. What molecular event explains the discrimination?
A The primer changes the allele before cycling
B A terminal mismatch can prevent efficient polymerase extension
C The mismatch creates a fluorescent protein
D The template migrates differently in agarose
Answer: B. A terminal mismatch can prevent efficient polymerase extension. Polymerase extension is sensitive to mismatches at the primer’s 3′ terminus.
A nested PCR gives a stronger target band but also increases false positives across runs. Which procedural change addresses the main risk?
A Reuse tips between reactions
B Open all first-round tubes beside reagent stocks
C Use separated pre- and post-amplification areas with contamination controls
D Remove the negative control
Answer: C. Use separated pre- and post-amplification areas with contamination controls. Physical separation and careful contamination control reduce carry-over of abundant first-round amplicons.
A qPCR melt curve shows two well-separated peaks in a SYBR assay. Before quantifying expression, what is the best interpretation?
A The assay needs no controls
B The higher peak proves a single target
C The fluorescence directly reports protein concentration
D More than one double-stranded product may be present and specificity needs evaluation
Answer: D. More than one double-stranded product may be present and specificity needs evaluation. SYBR reports any double-stranded DNA, so multiple melt peaks suggest nonspecific products or primer dimers.
A standard curve is linear across a broad dilution range but replicate Cq values vary mainly at the lowest concentration. What is a likely reason?
A Low-copy sampling variation and stochastic amplification
B Excessive chromosome number
C Agarose pore enlargement
D The primer has been translated
Answer: A. Low-copy sampling variation and stochastic amplification. At very low copy numbers, random template sampling can increase replicate variability.
A restriction digest produces the expected Southern blot band, but a second band appears only in samples with a duplicated locus. What does the extra band most likely represent?
A A protein contaminant
B An additional target-containing restriction fragment from the duplicated sequence
C A failed DNA transfer by definition
D An RNA primer
Answer: B. An additional target-containing restriction fragment from the duplicated sequence. A duplicated target can yield extra DNA fragments that hybridize to the probe.
In capillary Sanger sequencing, an overlapping double peak begins after one position in a cloned insert. What is a plausible cause?
A A lack of ddNTPs in every reaction
B A single pure sequence with no ambiguity
C A mixed template population or unresolved sequence variant/indel
D A Northern blot signal
Answer: C. A mixed template population or unresolved sequence variant/indel. Mixed templates or an indel can shift chromatogram peaks and produce overlapping signals.
A fluorescent in situ hybridization signal appears on two chromosome pairs, but the target is expected at one locus. What should be checked?
A The DNA ladder’s concentration
B The qPCR Cq threshold
C The antibody secondary reagent
D Probe specificity, hybridization stringency and possible repetitive sequence binding
Answer: D. Probe specificity, hybridization stringency and possible repetitive sequence binding. Cross-hybridization to related or repetitive sequences can create additional FISH signals.
A microarray probe shows no signal in any sample, including a positive control. Which technical explanation should be considered?
A Probe labeling, hybridization or scanner failure
B The target gene is absent from all organisms
C The probe must be a protein
D The genome has no DNA
Answer: A. Probe labeling, hybridization or scanner failure. A failed positive control points to an assay or platform problem rather than a sample-specific absence.
A digital PCR run has many saturated positive partitions. What change may help obtain a more informative count?
A Increase DNA concentration further
B Dilute the sample so target molecules are distributed across more negative partitions
C Remove the partitioning step
D Switch off the detector
Answer: B. Dilute the sample so target molecules are distributed across more negative partitions. Overloaded partitions reduce useful counting range; dilution can restore a measurable positive fraction.
A multiplex PCR yields the correct bands for two targets but suppresses the third. Which optimization is most defensible?
A Increase every primer concentration indefinitely
B Assume the third target is absent without controls
C Adjust the weak pair’s primer concentration or annealing conditions while rechecking all targets
D Change the gel stain only
Answer: C. Adjust the weak pair’s primer concentration or annealing conditions while rechecking all targets. Primer balance and pair-specific efficiency often need optimization in multiplex reactions.
A high-fidelity polymerase is selected for cloning a PCR product. What advantage is being sought?
A Direct RNA detection without reverse transcription
B Ability to amplify without primers
C Automatic sequencing of the product
D Lower probability of copying errors than a standard error-prone polymerase
Answer: D. Lower probability of copying errors than a standard error-prone polymerase. Proofreading high-fidelity enzymes reduce substitution errors during amplification.
A PCR product is cloned and several colonies are sequenced; one clone contains a point mutation. Which conclusion is justified?
A The sequence should be verified because polymerase errors can occur
B Every clone must carry the same mutation
C The gel size proves the nucleotide sequence
D The mutation is caused by the DNA ladder
Answer: A. The sequence should be verified because polymerase errors can occur. Correct fragment size does not establish sequence accuracy, so clone sequencing is useful.
A qPCR target and reference gene both shift by 2 Cq between matched samples. Under stable efficiency, what does ΔCq suggest?
A The target increased 4-fold relative to reference
B Their relative abundance may be similar after normalization
C The reference gene disappeared
D The reaction is necessarily contaminated
Answer: B. Their relative abundance may be similar after normalization. Equal shifts cancel in ΔCq, indicating little relative change under the comparative framework.
A DNA sample gives no band for the target and no band for an internal amplification control. Which interpretation should be favored?
A The target is conclusively present
B The target is conclusively absent
C The result may be invalid due to inhibition or reaction failure
D The ladder confirms the sample was extracted
Answer: C. The result may be invalid due to inhibition or reaction failure. Without the internal control, a negative target signal cannot be confidently separated from inhibition or failure.
A lab wants to add a restriction site to a PCR product without changing the target-binding portion. Where is the extra sequence placed?
A In the polymerase active site
B At the primer’s 3′ end instead of target complementarity
C In the DNA ladder
D At the 5′ end of one or both primers as a non-complementary tail
Answer: D. At the 5′ end of one or both primers as a non-complementary tail. A 5′ primer tail is copied into the product after the primer’s 3′ region anneals and extends.