PCR and Molecular Techniques MCQs (Set-4)

Difficulty: Hard

A sample has Cq 18 and a calibrator has Cq 23 for the same assay. Assuming near-perfect efficiency and comparable conditions, approximately how much more target did the sample start with?

A 5-fold
B 10-fold
C 16-fold
D 32-fold

A qPCR study compares two genes using ΔΔCq. Which assumption is important for the simple calculation?

A Target and reference assays have suitably similar amplification efficiencies
B Both genes must encode proteins of the same length
C The no-template control must amplify
D The samples must have identical fluorescence colors

An NTC develops a late amplification curve with a low-temperature melt peak, while samples show the expected higher-temperature peak. Which interpretation best fits?

A The NTC proves the samples are contaminated with target
B Likely primer-dimer signal in the NTC rather than the intended amplicon
C The samples contain no PCR product
D The positive control failed

A PCR assay detects a pathogen target, but the extraction control fails. How should the sample result be treated?

A As definitively positive
B As definitively negative
C As potentially invalid because successful extraction was not demonstrated
D As proof that the target mutated

After 30 ideal cycles from one starting DNA molecule, how many copies are predicted before accounting for real-world limits?

A 30 copies
B 30²
C 2 × 30
D 2³⁰

A researcher needs to distinguish two products that differ by only 8 bp near 100 bp. Which change is most likely to improve resolution?

A Use a higher-percentage agarose gel or an appropriate high-resolution gel system
B Use a much lower-percentage gel
C Add more template until the wells overflow
D Replace DNA stain with antibody

A PCR amplicon is much longer than the usual range for the selected polymerase. Which strategy is most appropriate?

A Shorten extension time to avoid errors
B Use a polymerase and extension program validated for long amplicons
C Remove one primer
D Replace dNTPs with ddNTPs

In endpoint PCR, sample A has a brighter band than sample B after many cycles. Why is this not automatically a reliable fold-change estimate?

A PCR never amplifies DNA exponentially
B The bands are proteins
C Both reactions may have reached different or similar plateaus
D Agarose cannot separate DNA

A probe-based qPCR assay produces fluorescence but the melt-curve check is unavailable. Which control remains important for detecting reagent contamination?

A Restriction digest of the product only
B Protein ladder
C No-primary-antibody control
D No-template control

A researcher designs one primer across a splice junction, but the junction lies too close to the primer’s 5′ end. What should be improved?

A Place the junction nearer the extendable 3′ end or use another validated design
B Move the primer entirely outside the transcript
C Remove the reverse primer
D Increase the DNA ladder concentration

A variant is detected by allele-specific PCR only when a 3′-matched primer is used. What molecular event explains the discrimination?

A The primer changes the allele before cycling
B A terminal mismatch can prevent efficient polymerase extension
C The mismatch creates a fluorescent protein
D The template migrates differently in agarose

A nested PCR gives a stronger target band but also increases false positives across runs. Which procedural change addresses the main risk?

A Reuse tips between reactions
B Open all first-round tubes beside reagent stocks
C Use separated pre- and post-amplification areas with contamination controls
D Remove the negative control

A qPCR melt curve shows two well-separated peaks in a SYBR assay. Before quantifying expression, what is the best interpretation?

A The assay needs no controls
B The higher peak proves a single target
C The fluorescence directly reports protein concentration
D More than one double-stranded product may be present and specificity needs evaluation

A standard curve is linear across a broad dilution range but replicate Cq values vary mainly at the lowest concentration. What is a likely reason?

A Low-copy sampling variation and stochastic amplification
B Excessive chromosome number
C Agarose pore enlargement
D The primer has been translated

A restriction digest produces the expected Southern blot band, but a second band appears only in samples with a duplicated locus. What does the extra band most likely represent?

A A protein contaminant
B An additional target-containing restriction fragment from the duplicated sequence
C A failed DNA transfer by definition
D An RNA primer

In capillary Sanger sequencing, an overlapping double peak begins after one position in a cloned insert. What is a plausible cause?

A A lack of ddNTPs in every reaction
B A single pure sequence with no ambiguity
C A mixed template population or unresolved sequence variant/indel
D A Northern blot signal

A fluorescent in situ hybridization signal appears on two chromosome pairs, but the target is expected at one locus. What should be checked?

A The DNA ladder’s concentration
B The qPCR Cq threshold
C The antibody secondary reagent
D Probe specificity, hybridization stringency and possible repetitive sequence binding

A microarray probe shows no signal in any sample, including a positive control. Which technical explanation should be considered?

A Probe labeling, hybridization or scanner failure
B The target gene is absent from all organisms
C The probe must be a protein
D The genome has no DNA

A digital PCR run has many saturated positive partitions. What change may help obtain a more informative count?

A Increase DNA concentration further
B Dilute the sample so target molecules are distributed across more negative partitions
C Remove the partitioning step
D Switch off the detector

A multiplex PCR yields the correct bands for two targets but suppresses the third. Which optimization is most defensible?

A Increase every primer concentration indefinitely
B Assume the third target is absent without controls
C Adjust the weak pair’s primer concentration or annealing conditions while rechecking all targets
D Change the gel stain only

A high-fidelity polymerase is selected for cloning a PCR product. What advantage is being sought?

A Direct RNA detection without reverse transcription
B Ability to amplify without primers
C Automatic sequencing of the product
D Lower probability of copying errors than a standard error-prone polymerase

A PCR product is cloned and several colonies are sequenced; one clone contains a point mutation. Which conclusion is justified?

A The sequence should be verified because polymerase errors can occur
B Every clone must carry the same mutation
C The gel size proves the nucleotide sequence
D The mutation is caused by the DNA ladder

A qPCR target and reference gene both shift by 2 Cq between matched samples. Under stable efficiency, what does ΔCq suggest?

A The target increased 4-fold relative to reference
B Their relative abundance may be similar after normalization
C The reference gene disappeared
D The reaction is necessarily contaminated

A DNA sample gives no band for the target and no band for an internal amplification control. Which interpretation should be favored?

A The target is conclusively present
B The target is conclusively absent
C The result may be invalid due to inhibition or reaction failure
D The ladder confirms the sample was extracted

A lab wants to add a restriction site to a PCR product without changing the target-binding portion. Where is the extra sequence placed?

A In the polymerase active site
B At the primer’s 3′ end instead of target complementarity
C In the DNA ladder
D At the 5′ end of one or both primers as a non-complementary tail