Renewable Energy Systems MCQs (Set-3)

A 2 m² PV panel receives 800 W/m² at 20% efficiency. Estimate output.

A 320 W
B 160 W
C 800 W
D 1600 W

Four PV modules rated 40 V each are connected in series. Find string voltage.

A 40 V
B 80 V
C 160 V
D 200 V

Three identical 5 A PV strings are connected in parallel. Find total current.

A 5 A
B 15 A
C 10 A
D 20 A

A PV array outputs 240 W at 30 V. Find current.

A 4 A
B 8 A
C 6 A
D 12 A

A 1 kW PV module has a -0.4%/°C power coefficient. Estimate power 25°C hotter.

A 900 W
B 800 W
C 950 W
D 1000 W

A 100 kW plant generates 150 MWh in one year. Approximate capacity factor.

A 8.6 percent
B 25 percent
C 17.1 percent
D 50 percent

Below rated operation, what happens to ideal wind power if speed doubles?

A It doubles
B It quadruples
C It increases sixfold
D It increases eightfold

A wind rotor has a 10 m radius. Approximate swept area.

A 314 m²
B 31.4 m²
C 100 m²
D 628 m²

What is the Betz-limit maximum fraction of wind power?

A 1 over 2
B 16 over 27
C 3 over 4
D 1 over 1

A hydro plant has Q 10 m³/s, head 5 m, and efficiency 0.8. Estimate output.

A 98 kW
B 392 kW
C 245 kW
D 490 kW

After a P&O voltage step, measured PV power falls. What should it do next?

A Keep stepping same way
B Disconnect the inverter
C Short the PV array
D Reverse perturbation direction

At the PV maximum-power point, what relation holds for incremental conductance?

A dI/dV equals minus I/V
B dI/dV equals I/V
C dI/dV equals zero
D I/V equals zero

Why can partial shading create multiple PV power peaks?

A Wind speed changes suddenly
B Bypass paths alter string curve
C Grid frequency doubles
D Battery voltage becomes zero

How does a grid-connected inverter exchange active power?

A Changes water head
B Changes module temperature
C Controls synchronized current
D Moves turbine yaw

Why is battery round-trip efficiency below 100%?

A Energy is created
B Voltage cannot change
C Cells store all input
D Charging and conversion losses

What defines an islanded microgrid operating condition?

A All sources are shut down
B Grid frequency is infinite
C Local grid section is disconnected
D Only PV modules remain

A storage system supplies 10 kW for 4 hours. Required usable energy is?

A 40 kWh
B 2.5 kWh
C 14 kWh
D 400 kWh

What does solar thermal collector orientation mainly optimize?

A Grid phase angle
B Wind rotor torque
C Battery cycle count
D Incident solar energy capture

What does variable-speed wind control often optimize below rated power?

A Tip-speed ratio
B Battery C-rate
C Hydro head
D Grid pole count

How does feedstock moisture affect biomass conversion?

A Raises silicon voltage
B Increases wind shear
C Can lower usable heating value
D Sets grid phase

Why do evacuated-tube collectors reduce heat loss?

A Higher wind speed
B Larger grid current
C Reduced convective heat transfer
D Lower fluid flow

What drives hydropower output for fixed efficiency?

A PV temperature only
B Wind pitch only
C Battery voltage only
D Flow rate and head

What is a common reason for multiple renewable sources in a hybrid plant?

A Remove all controls
B Improve supply complementarity
C Guarantee constant weather
D Eliminate conversion losses

What does a renewable forecast help a grid operator schedule?

A Blade material
B PV cell doping
C Penstock diameter
D Balancing resources

Why does PV output fall when irradiance falls?

A Photocurrent decreases
B Wind torque decreases
C Hydro head rises
D Grid frequency drops