Air conditioning controls temperature, humidity and what?
A Air cleanliness
B Refrigerant color
C Compressor bore
D Fuel quality
Answer: A. Air cleanliness. Air conditioning treats air for thermal comfort and indoor air quality.
A cooling load calculation estimates what?
A Compressor oil volume
B Required heat removal
C Duct color
D Refrigerant toxicity
Answer: B. Required heat removal. Cooling load is the rate of heat that must be removed to maintain conditions.
An air-handling unit commonly contains filters, coils and what?
A Fans
B Engine pistons
C Fuel injectors
D Gear trains
Answer: A. Fans. An AHU conditions and moves air using filters, coils, fans and dampers.
An air filter removes what from supply air?
A Water vapor only
B Refrigerant
C Shaft heat
D Particulate matter
Answer: D. Particulate matter. Filters capture airborne particles to improve indoor air quality and protect equipment.
A blower in an air system provides what?
A Refrigeration effect
B Liquid storage
C Airflow and pressure
D Humidity measurement
Answer: C. Airflow and pressure. Fans and blowers move air through ducts and overcome system resistance.
Duct static pressure is a measure of what?
A Air temperature only
B Moisture content
C Refrigerant enthalpy
D Air pressure relative to ambient
Answer: D. Air pressure relative to ambient. Static pressure is the pressure exerted by air independent of its local velocity direction.
A diffuser is used to distribute supply air and reduce what?
A Cooling capacity
B Drafts
C Humidity ratio
D Refrigerant pressure
Answer: B. Drafts. A diffuser spreads supply air and promotes mixing while limiting drafts.
Return air travels from conditioned space back to what?
A Outdoor condenser
B Air-handling system
C Expansion valve
D Cooling tower
Answer: B. Air-handling system. Return ducts bring room air back to the AHU for recirculation or treatment.
Outdoor air dampers regulate what entering an AHU?
A Ventilation air
B Refrigerant liquid
C Compressor oil
D Condensate only
Answer: A. Ventilation air. Outdoor air dampers control fresh-air intake.
A variable-air-volume system controls room load by changing what?
A Refrigerant type
B Supply airflow
C Duct material
D Condenser water chemistry
Answer: B. Supply airflow. VAV terminals vary air volume to meet zone demand.
An economizer provides free cooling using suitable what?
A Outdoor air
B Hot refrigerant gas
C Compressor discharge
D Boiler steam
Answer: A. Outdoor air. An air-side economizer increases outdoor air when conditions can reduce mechanical cooling.
A cooling tower rejects heat mainly by what?
A Water evaporation
B Radiation only
C Fuel combustion
D Compression
Answer: A. Water evaporation. Evaporation of a small portion of circulating water cools the remaining water.
An absorption refrigerator is driven mainly by what input?
A Mechanical shaft work only
B Battery power only
C Heat
D Compressed air
Answer: C. Heat. Absorption systems use heat to drive refrigerant separation and circulation.
In a water-lithium-bromide system, the refrigerant is what?
A Lithium bromide
B Ammonia
C Air
D Water
Answer: D. Water. Water is the refrigerant and lithium bromide is the absorbent.
In an ammonia-water absorption system, the refrigerant is what?
A Water only
B Lithium bromide
C Glycol
D Ammonia
Answer: D. Ammonia. Ammonia is the refrigerant and water is the absorbent.
An absorber combines refrigerant vapor with what?
A Absorbent solution
B Outdoor air
C Compressor oil
D Cooling coil condensate
Answer: A. Absorbent solution. The absorber dissolves refrigerant vapor into the absorbent.
A generator separates refrigerant from solution using what?
A Heat input
B Expansion work
C Duct suction
D Filter pressure
Answer: A. Heat input. Heat drives refrigerant vapor out of the rich solution in the generator.
A solution pump in absorption systems raises what?
A Air humidity
B Solution pressure
C Refrigerant temperature only
D Cooling load
Answer: B. Solution pressure. The pump moves liquid solution from low to high pressure.
A reversible heat pump can provide cooling by reversing what?
A Compressor rotation always
B Duct material
C Refrigerant flow path
D Air filter direction
Answer: C. Refrigerant flow path. A reversing valve switches indoor and outdoor coil roles.
A heat-pump defrost cycle removes what from outdoor coil?
A Oil film
B Duct dust
C Frost
D Liquid refrigerant
Answer: C. Frost. Defrost temporarily warms the outdoor coil to melt accumulated frost.
Refrigerant safety classification considers toxicity and what?
A Color
B Flammability
C Boiling noise
D Pipe length
Answer: B. Flammability. Safety groups account for toxicity and flammability characteristics.
Ozone-depletion potential is associated with which environmental effect?
A Global cooling only
B Water hardness
C Stratospheric ozone damage
D Noise pollution
Answer: C. Stratospheric ozone damage. ODP compares a substance’s potential to deplete stratospheric ozone.
Evaporative cooling is most effective in what climate?
A Cold and humid
B Cool and saturated
C Hot and dry
D Any climate equally
Answer: C. Hot and dry. Dry air can accept more water vapor, allowing strong evaporative cooling.
A supply-air grille mainly performs what function?
A Stores refrigerant
B Measures humidity
C Rejects condenser heat
D Directs air into room
Answer: D. Directs air into room. Grilles direct supply or return airflow and may provide adjustable vanes.
A condensate drain removes water from which component?
A Compressor crankcase
B Condenser fan
C Expansion valve
D Cooling coil
Answer: D. Cooling coil. Condensed moisture from a cooling coil drains through a condensate line.