Electromagnetic Induction — Short Notes
Changing magnetic flux produces induced emf; the induced effect opposes the change that causes it.
1. Magnetic flux
- Magnetic flux through a surface is ΦB = ∫B · dA. For a uniform field through a flat loop, ΦB = BA cos θ, where θ is between B and the area normal.
- Flux can change if field strength changes, the loop area changes, or the angle between the field and surface changes.
- The SI unit is the weber (Wb = T m²). Use signed flux consistently when applying Faraday’s law.
2. Faraday’s law and Lenz’s law
- The induced emf in a coil of N turns is ε = −N dΦB/dt. A changing flux is required; a steady field through a stationary loop gives no induced emf.
- The minus sign expresses Lenz’s law: the induced current produces a magnetic effect that opposes the change in flux, not necessarily the original field itself.
- Lenz’s law is a consequence of energy conservation. Determine first whether flux into or out of the surface is increasing or decreasing, then find the induced field and current direction.
- If resistance is R and induced emf is ε, the induced current magnitude is I = |ε|/R for a simple resistive loop.
3. Motional emf
- A conductor of length ℓ moving at speed v perpendicular to a uniform magnetic field B can develop a motional emf |ε| = Bℓv, when motion, field and conductor are mutually perpendicular.
- Charges in the moving conductor experience magnetic force q(v × B), separating charge until an electric field balances the force in open circuit.
- For other geometries, use the magnetic-force direction and the rate of change of flux rather than applying Bℓv blindly.
4. Self-inductance
- A changing current in a circuit changes its own magnetic flux and induces a back emf. For constant self-inductance, εL = −L dI/dt.
- Inductance L depends on circuit geometry and magnetic environment. Its SI unit is the henry (H).
- For an ideal inductor, stored magnetic energy is UB = ½LI². An inductor resists changes in current, not current itself.
5. Mutual inductance and transformers
- Changing current in one coil can induce emf in a nearby coil. With constant mutual inductance M, ε₂ = −M dI₁/dt.
- An ideal transformer uses changing magnetic flux linking primary and secondary coils. For sinusoidal operation, voltage ratio is approximately Vs/Vp = Ns/Np; ideal power is conserved, so VpIp = VsIs.
- A transformer requires changing flux; a steady DC input does not sustain transformer emf after the transient.
6. Eddy currents and applications
- Changing flux within a bulk conductor induces circulating eddy currents. They can cause heating and magnetic drag.
- Laminating a transformer core reduces eddy-current paths and associated energy loss. Eddy-current braking and induction heating make use of the same effect.
- Generators use relative motion between coils and magnetic fields to create changing flux and induced emf.
7. Formula recap
| Concept | Relation | Conditions / note |
|---|---|---|
| Magnetic flux | ΦB = BA cos θ | Uniform field, flat area |
| Faraday’s law | ε = −N dΦB/dt | Coil of N turns |
| Motional emf | |ε| = Bℓv | Mutually perpendicular geometry |
| Self-induced emf | εL = −L dI/dt | Constant L |
| Inductor energy | UB = ½LI² | Ideal inductor |
| Transformer voltage ratio | Vs/Vp = Ns/Np | Ideal transformer |
8. Common checks
- Track whether flux itself or its magnitude is changing; the induced effect opposes the change.
- Use the area normal to define the angle in BA cos θ.
- Distinguish self-induction in one circuit from mutual induction between circuits.
- Check the geometry assumptions before using the shortcut Bℓv.