An inlet flow suddenly increases while outlet flow initially stays unchanged. What happens first to tank inventory?
A It becomes zero
B It starts decreasing
C It starts increasing
D It remains fixed
Answer: C. It starts increasing. The positive difference between inlet and outlet gives positive accumulation.
How is a step change in an input applied in its ideal mathematical model?
A Sudden sustained change
B Slow continuous ramp
C Instant return to baseline
D One finite-width oscillation
Answer: A. Sudden sustained change. A step jumps immediately to a new value and holds there.
What does a large first-order time constant indicate at the same gain and without delay?
A A larger final change
B An inverse final value
C A faster response
D A slower response
Answer: D. A slower response. A larger time constant spreads the same normalized response over a longer duration.
What is transport dead time?
A Time to reach half value
B Delay before response begins
C Final sensor error
D Complete reaction time
Answer: B. Delay before response begins. Dead time shifts the beginning of a response without itself altering the subsequent response shape for a pure delay.
What does a process state variable represent within a dynamic model?
A Current internal condition
B Only an equipment tag
C The source of all inputs
D A final purchase value
Answer: A. Current internal condition. A state variable, such as tank level, carries information needed to predict future evolution under known inputs.
Which quantity is zero for a state at steady operation?
A External pressure
B Input value always
C State value always
D Time derivative
Answer: D. Time derivative. A steady state has constant state values, so their derivatives with respect to time vanish.
How does a stable self-regulating process respond to a small sustained step?
A Ramps forever by definition
B Oscillates without decay
C Approaches a finite new value
D Exits its domain immediately
Answer: C. Approaches a finite new value. A stable self-regulating process tends toward a new equilibrium when the new operating condition is held.
An operator applies a temporary change and then restores the original input. What ideal input resembles this?
A Permanent step
B Pulse
C Unending ramp
D Steady bias only
Answer: B. Pulse. A rectangular pulse lasts for a finite interval before returning to baseline.
Where is process gain read from a stable step test?
A Initial absolute value
B Final change ratio
C Signal noise frequency
D Time to first response
Answer: B. Final change ratio. Steady process gain is the final output change divided by the sustained input change.
A steam-heated tank is modeled dynamically. Which state describes its stored thermal energy when properties and mass are fixed?
A Ambient air density only
B Pump model number
C Steam supply valve tag
D Tank temperature
Answer: D. Tank temperature. Stored sensible energy changes with the uniform tank temperature when mass and heat capacity are fixed.
Why does a tank with an outlet restriction often show lag after inlet flow changes?
A Liquid inventory must change
B Its volume changes instantly
C Outlet flow has no resistance
D The inlet is purely imaginary
Answer: A. Liquid inventory must change. Material accumulates first, changing level and then affecting outlet flow.
Which relationship applies to a linear model’s response to the sum of two independent input signals at zero initial deviation?
A Individual responses add
B Only the larger response remains
C The responses multiply
D The response becomes zero
Answer: A. Individual responses add. Linearity permits superposition of the responses produced by each signal.
Which process configuration can introduce a transport delay?
A Instant local measurement
B Zero-length pipe
C Long downstream sampling line
D Direct electronic calculation
Answer: C. Long downstream sampling line. The sample needs time to travel from the process to the measurement location.
What response is typical of an ideal integrator to a sustained nonzero step?
A A ramp
B A finite exponential plateau
C A vanished output
D A momentary spike only
Answer: A. A ramp. The integrator accumulates a constant input, producing a change proportional to elapsed time.
What does a dynamic process model describe?
A Equipment price only
B Changes with time
C Steady costs only
D Material names only
Answer: B. Changes with time. A dynamic model predicts how state or output variables evolve over time.
How does a deviation variable differ from its physical process variable?
A The signal is always positive
B Baseline is subtracted
C Sensor noise is removed automatically
D Units are always squared
Answer: B. Baseline is subtracted. A deviation is the actual process value minus its selected operating-point value.
What differentiates a ramp input from a single step input?
A It jumps then holds
B It is zero forever
C It changes at constant slope
D It moves randomly
Answer: C. It changes at constant slope. An ideal ramp increases or decreases linearly in time.
If a vessel’s inlet and outlet temperature match at one instant, what additional information is needed before declaring all states steady?
A The equipment paint color
B Only the valve tag
C Rates of accumulation
D Only the pipe length
Answer: C. Rates of accumulation. Steady state is a condition on rates of change, so coincident readings alone do not establish it.
A valve opening increases and the eventual tank level increases. What sign is the local steady gain from valve opening to level?
A Zero
B Undefined in all cases
C Negative
D Positive
Answer: D. Positive. The output and input changes have the same sign, so their ratio is positive.
What assumption makes an ideal stirred-tank concentration model simpler?
A Its feed never changes
B Species cannot enter or leave
C Its contents are uniform
D Its volume is always zero
Answer: C. Its contents are uniform. Perfect mixing lets one tank composition represent the contents and outlet in the balance.
Why can a process be at steady state while material continues to flow?
A Every inlet is closed
B All flow stops internally
C Flows and effects balance
D Time has no units
Answer: C. Flows and effects balance. Steady conditions mean no net accumulation. Opposing flow and reaction terms can balance.
Inside a proportional level model, which coefficient converts height into volume for a tank with vertical sides?
A Liquid viscosity
B Tank diameter alone
C Vapor pressure
D Cross-sectional area
Answer: D. Cross-sectional area. For constant area A, liquid inventory volume is Ah.
Which equation order characterizes an ideal single-capacity linear lag?
A Third order
B Zero order
C Second order
D First order
Answer: D. First order. One independent storage state leads to one first-order differential equation in the simple lag model.
Why are initial conditions needed for many dynamic simulations?
A They specify starting states
B They determine all future inputs
C They eliminate derivative terms
D They choose equipment materials
Answer: A. They specify starting states. The same model and inputs can produce different trajectories from different starting inventories.
What kind of model is used when process behavior is expressed as an output-to-input ratio in the Laplace domain?
A Batch recipe
B Transfer function
C Phase diagram
D Cost correlation
Answer: B. Transfer function. A transfer function is the linear ratio of transformed output deviation to transformed input deviation at zero initial deviation.